6. TECHNICAL DATA
Frequency:
Standard:
433,500 MHz
Optional:
from 433,050 to 434,790 MHz (in the 70 cm Band)
RF Output Power:
TED-TX10 ................. 10 mW
TED-TX400 ............... 400 mW
Reach:
TED-TX10 ................. about 1,5 km
TED-TX400 ............... about. 5 km
Impulse Input TED-TX:
active low, min. 10 ms, double impulse protection time about 50 ms
Impulse Output TED-RX:
active low, 100 ms
Power Supply:
external:
TED-TX10 and TED-RX: +6,5 to 28 Volt DC
TED-TX400:
+9 to 15 Volt DC
internal:
6 x Alkaline Batteries 1,5 V (type AA) or
6 x NiCd Rechargeable Batteries 1,2 V (type AA)
Power Consumption:
TED-TX10:
in Transmission Mode:
about 35 mA
in Stand-by Mode:
about 3 mA
TED-TX400: in Transmission Mode:
about 300 mA
in Stand-by Mode:
about 3 mA
TED-RX:
Normal Mode:
about 35 mA
Test Mode:
about 70 mA
Working Time:
Table for use with Alkaline Batteries (Type Energizer) at 25°C (77F):
Table for use with NiCd batteries (Type Panasonic 700m Ah) at 25°C (77F):
TED-TX10
without photcell
1 impulse per minute
about 300 hours
TED-TX10
with photocell
1 impulse per minute
about 66 hours
TED-TX10
---
1 data transmission per minute about 270 hours
TED-TX10
---
continues data transmission
about 54 hours
TED-TX400 without photcell
1 impulse per minute
about 270 hours
TED-TX400
with photocell
1 impulse per minute
about 60 hours
TED-TX400
---
1 data transmission per minute about 54 hours
TED-TX400
---
continues data transmission
about 6 hours
TED-RX
---
in all equal
about 54 hours
TED-TX10
without photcell
1 impulse per minute
about 100 hours
TED-TX10
with photocell
1 impulse per minute
about 22 hours
TED-TX10
---
1 data transmission per minute about 90 hours
TED-TX10
---
continues data transmission
about 18 hours
TED-TX400 without photcell
1 impulse per minute
about 90 hours
TED-TX400
with photocell
1 impulse per minute
about 20 hours
TED-TX400
---
1 data transmission per minute about 18 hours
TED-TX400
---
continues data transmission
about 2 hours
TED-RX
---
in all equal
about 18 hours
Содержание TELEDATA TED-RX