TED-TX / RX
Page 12
3.2. Switching on:
Normal Mode:
- switch device-switch (11) on
- TED works in the impulse transmission mode
Test-Mode:
- press device-key (10)
- device-switch (11) to position ON, LED (3) must blink
- release device-key (10)
- test mode switches automatically off after one minute,
manually you can switch it off with device-key (10).
Impulse Transmission:
device-switch (11) to position ON, LED (3) must blink
Data Transmission ALGE 1 Sec.:
-
device-switch (11) to position ON, LED (3) must blink
-
when a data string with the right format arrives at the
TED-TX it switches to this mode.
Data Transmission ALGE 0.1 Sec.: - set code switch (12) from TED-TX and RX on position 1
- device-switch (11) to position ON, LED (3) must blink
Data Transmission 2400 Baud:
- set code switch (12) from TED-TX and RX on position 3
- device-switch (11) to position ON, LED (3) must blink
- transmission of each data string with 2400 Baud
- each data string needs a code at the start and end
Data Transmission 4800 Baud:
- set code switch (12) from TED-TX and RX on position 4
- device-switch (11) to position ON, LED (3) must blink
- transmission of each data string with 4800 Baud
- each data string needs a code at the start and end
Data Transmission "Direct":
- set code switch (12) from TED-TX and RX on position 6
- device-switch (11) to position ON, LED (3) must blink
- transmission of each data string (with 2400 or 4800 Baud)
3.3. Choosing the Operation Modes:
You get as well into the signal strength test by making three short cuts between the green (5) and
black (6) banana socket within a short time..
Switch
Signale Mode
Data Mode
position 0: data transmission ALGE 1 sec.
position 1: data transmission ALGE 0.1 sec.
position 0 to 9
position 2: no function
code switch (12)
to select the
position 3: data transmission 2400 Baud
timing channel
position 4: data transmission 4800 Baud
position 6: data transmission direct
position 7 to 9: no function
code switch (9)
for address
for address
device key (10) field strength on/off transmit last data string again