TED-TX / RX
Page 20
4.7. Impulse Transmission for more than two Timing Channels with RX-C10:
With the TdC 8000 and Timer S4 you can receive together with the RX-C10 from the TED-RX up to
10 different timing channels. Therefore you need different TED-TX. You can transmit a maximum of
two timing channels per TED-TX. At each TED-TX you need to adjust the timing channels with
code-switch (12).
You must notice, that each timing impulse blocks the transmitter and receiver for 0.1 seconds. A
further impulse from another transmitter will be ignored during this time.
Timing Channel selection with Code-Switch (12) at the TED-TX:
You need to adjust the timing channel only at the TED-TX (transmitter). You need to adjust the
timing channels with code-switch (12). Each switch position has two timing channels.
Set the switch with the small screw driver delivered together with the TED.
The switch position is shown with the arrow. The ALGE setup is always
on position 0 (e.g. picture to the left).
TED-TX
TED-TX timing channel
TED-TX DIN-socket
TED-TX DIN-Stecker
Code-Schalter (12)
banana socket
timing channel
timing channel
green (5) and black (6)
on pin 1
on pin 2
switch position = 0
0
0
1
switch position = 1
1
1
2
switch position = 2
2
2
3
switch position = 3
3
3
4
switch position = 4
4
4
5
switch position = 5
5
5
6
switch position = 6
6
6
7
switch position = 7
7
7
8
switch position = 8
8
8
9
switch position = 9
0
0
2
Содержание TELEDATA TED-RX
Страница 1: ...TELEDATA TED TX TED RX English ...
Страница 9: ...TED TX RX Page 9 Version E 2000 03 02 Page 9 ...