TED-TX / RX
Page 25
Version: E-2000-03-02
Page 25
5.2. Data Transmission 0.1 Seconds:
Adjustment:
Set code-switch (12) on position 1
Each data transmission of a data string from the TED-TX to the TED-RX happens once. Each data
string has a check sum. If the TED-RX receives the data with the correct check sum it output the
data. This mode allows to transmit ten data string per second.
This Mode is used to have the transmitted data immediately present (delay of 0.1 seconds) or when
you need to transmit a running time. The transmission safety is not as high as with the "data trans-
mission 1 second".
5.2.1. Data Transmission from an ALGE Timer to an ALGE Display Board:
The timer controls the display board by radio.
With cable 010-10 the TED-TX will not be powered by the ALGE Timer.
With cable 000-10 the TED-RX will not be powered by the ALGE Display Board.
With cable 107-10 the TED-TX will be powered by the ALGE Timer.
With cable 103-10 the TED-RX will be powered by the ALGE Display Board.