TED-TX / RX
Page 21
Version: E-2000-03-02
Page 21
e.g.: Timing with 10 timing channels on test slope for skiing:
A separate TED-TX is used for each timing channel (all together 10 TED-TX).
A Startgate is used for the start.
A photocell is used for the intermediate times and the finish.
A TdC 8000 is used as timer
Connect the RX-C10 at the TdC 8000 (connection "Multi Channel") and TED-RX.
The code-switch (12) of the TED-RX has no function (switch position does not matter).
Timing
Function
Impulse
Switch Position
Cable
Socket
Channel
Trigger
Code-Switch (12)
Type
of TED-TX
C0
Start
Startgate
0
000-10
Banana Socket 5 + 6
C2
Intermediate Time 1
Photocell
1
001-10
DIN-Socket (7)
C3
Intermediate Time 2
Photocell
2
001-10
DIN-Socket (7)
C4
Intermediate Time 3
Photocell
3
001-10
DIN-Socket (7)
C5
Intermediate Time 4
Photocell
4
001-10
DIN-Socket (7)
C6
Intermediate Time 5
Photocell
5
001-10
DIN-Socket (7)
C7
Intermediate Time 6
Photocell
6
001-10
DIN-Socket (7)
C8
Intermediate Time 7
Photocell
7
001-10
DIN-Socket (7)
C9
Intermediate Time 8
Photocell
8
001-10
DIN-Socket (7)
C1
Finish
Photocell
0
001-10
DIN-Socket (7)