Motor current indicates when the separator
has come to full speed.
During start the current reaches a peak and
then slowly drops to a low and stable value.
For normal length of the start-up period see
‘‘8.2 Technical data” on page 121
.
WARNING
Disintegration hazards
When excessive vibration occurs,
keep
liquid feed on
and
stop
separator.
The cause of the vibrations must be
identified and corrected before the separator
is restarted.
Excessive vibrations may be due to incorrect
assembly or poor cleaning of the bowl.
S00
0962
1
Current increases when the coupling engages...
S0
0096
31
.... to decrease to a stable value when full speed has
been reached