background image

 

 
 
 
 

AUTO PURE WATER PURIFIER 

WA / WC / WB / WG SERIES 

MODEL 

WA301/311 Series 
WC301/311 Series 
WB301/311 Series 

WG301/311 Series 

 

INSTRUCTION MANUAL 

- FIRST EDITION – 

 

  Thank you for purchasing WA / WC / WB / WG Series Auto Pure 

Water Purifier of Yamato Scientific. 

 

  To use this unit properly, read this "Instruction Manual" thoroughly 

before using this unit. Keep this instruction manual around this unit 

for referencing at any time. 

 

WARNING: Carefully read and thoroughly understand the important 

warning items described in this manual before using this unit. 

 

 

 

 

 

Yamato Scientific America Inc. 

Santa Clara, CA 

 

Содержание WA Series

Страница 1: ...Series Auto Pure Water Purifier of Yamato Scientific To use this unit properly read this Instruction Manual thoroughly before using this unit Keep this instruction manual around this unit for referen...

Страница 2: ...S 21 DISPENSING OPERATIONS 23 MAIN MENU SERVICE CONFIGURATION 26 CONFIGURATION MENU 27 SYSTEM AND INFORMATION EVENT LOGS 29 MAINTENANCE 30 HEALTH STATUS 31 CONSUMABLE REPLACEMENT 33 FILTER DETECTION A...

Страница 3: ...r is removed prior to accessing the side panel to perform any UV maintenance Make sure gloves are used when handling the UV bulb Gloves must be worn when handling the UV bulb Which protects the integr...

Страница 4: ...ransition from Polishing mode to Stand By mode and the recirculation pump solenoid and UV if installed will be automatically turned off via the PLC Controller The main screen provides resistivity TOC...

Страница 5: ...3 MODEL TYPES...

Страница 6: ...econdary Port on the side of the system Used to feed ancillary equipment such as analyzers and scientific equipment Internal pressure switch automatically keeps the system operating during a water dra...

Страница 7: ...1 0 amp 220 VAC 50 Hz 0 5 amp Dedicated GFCI protected outlet six feet within the system FEED WATER PRESSURE 20 90 PSIG regulated If gravity feed water is used an external delivery pump with auto shut...

Страница 8: ...ation System Or Remote Configuration WA WC WB WG Auto Pure Water Purification System with side remote connections Remote Configuration Control Unit with Arm tubing electrical bundle Mounting Hardware...

Страница 9: ...si pressure gauge 300 grade stainless steel for diagnostics not included Tube Cutter 2 Phillips Head Screwdriver Teflon Tape Basic Hand tools adjustable wrench pliers socket wrench etc Tie wraps Optio...

Страница 10: ...tabs pointing up Align slots in system back plate with tabs on mounting bracket Insert tabs into slots and slowly lower system Ensure all tabs are fully engaged and base of system is parallel to floo...

Страница 11: ...ivot joints The tubing and electrical bundle is approximately 1 in diameter If a penetration through a sink is needed for an under the sink configuration a minimum of 1 1 2 hole is required for the fl...

Страница 12: ...tabs are aligned push and turn to lock connector in place Power switch is located on left side of system Ensure power switch is in OFF position Insert power cord into electrical connection module Inse...

Страница 13: ...TION Wear gloves when handling the UV bulb to avoid contamination and reduced service life CAUTION Never look directly at the UV bulb while in operation An LED located by the dual pack mechanism is pr...

Страница 14: ...t flow from the direct feed outlet port Direct Feed Side Port Male CPC Quick Fitting The female side has a short 3 8 bulkhead connection with an internal check valve The male side with O Ring is shipp...

Страница 15: ...through a supplied 0 2 micron capsule filter The gun has a mounting bracket on the right side of the system With this option the gun is treated like a direct feed and a pressure switch will turn the...

Страница 16: ...Yellow Partial life Red Needs replacement Press and hold any component to display See MAINTENANCE Section for more details 5 RECIRCULATION MODE Initial Rinse Polish Standby Direct Feed 6 ALARM STATUS...

Страница 17: ...UAL CONDITIONING CART 3 DRAIN CONNECTION 4 CONTROL PANEL 5 DISPENSE PORT WITH FILTER POLISHING CART LEVER 6 POLISHING CART 1 POLISHING CARTRIDGE 2 DUAL CONDITIONING CARTRIDGE 3 SUB MICRON FINAL FILTER...

Страница 18: ...stallation 1 Remove plastic plugs from the top of the cartridge pack 2 Lift the lever on the left side of the mechanism 3 Insert conditioning cartridge Align base of cartridge with the contour in the...

Страница 19: ...with connections facing into the system Label should be facing out Flanges on the side of the cartridge will rest on the alignment guide Alignment guide 4 Push cartridge towards system until it stops...

Страница 20: ...these components will be greyed out on the Home Screen Display Ensure feed water supply is on and connected to system Turn on power switch Splash screen will display For the first time select Installa...

Страница 21: ...be factory installed The bulb will need to be activated on this initial start up which will set the installation date From the Home Screen press and hold the UV Bulb icon Press NEXT to continue Follo...

Страница 22: ...Screen From the Home Screen press and hold the POLISHING icon Press NEXT to continue Follow instructions displayed As this is the first time initialization process a new filter should have been insta...

Страница 23: ...r internally to maintain water purity The system continuously monitors water quality system performance and consumable health System parameters for recirculation can be adjusted See Recirculation Adju...

Страница 24: ...r quality after 5 seconds Following Polishing the system will automatically enter Standby mode and will display WAKE This is a 14 minute dwell to conserve system power and consumables If equipped with...

Страница 25: ...e and Polishing Cartridge See the Direct Feed Connection Section Water can be dispensed from the main outlet port during direct feed operation However access to service the consumables will be disable...

Страница 26: ...volumetric batch and assign a discrete label The batch dispense screen will have six dispense buttons If programed pressing the batch number will initiate the volumetric fill and will stop automatical...

Страница 27: ...in the desired amount of milliliters and press ENT This will take you back to the program screen Before saving proceed to the batch label instructions To enter the Batch Label press the empty square f...

Страница 28: ...component replacement and sanitization Screen 2 provides information on the equipment and service contact along with the advance service tab The advanced service tab is password protected with the co...

Страница 29: ...are 2 0 Megohm for R1 and 10 Megohm for R2 The user can change these alarm set points Maximum set point allowed for conditioning is 10 M and 14 M for polishing To adjust the set points Home Screen Pre...

Страница 30: ...system will toggle between Polishing and Standby The Polishing mode will turn on the pump resistivity measurement and UV if this option is installed The Standby mode will turn off the pump and UV to...

Страница 31: ...ith a description and date stamp User can toggle up and down to view the full list A log item can be cleared This is password protected using 4321 and pressing CLEAR If the system is in an Alarm Condi...

Страница 32: ...N FREQUENCY ARI PX135001 or ARI PX135002 Conditioning cartridge Semi annually ARI PX115103 or ARI PX115104 Polishing Cartridge Semi annually ARI PF006402 or ARI PF007101 0 2 micron capsule filter Semi...

Страница 33: ...is adjusted see Resistivity Alarm Setup yellow health meter color will appear at the new set point The default elapse time for both the conditioning pack and polishing cartridge is six months This may...

Страница 34: ...portional remaining life over this time period as shown below LIFE REMAINING HEALTH METER COLOR 05 m Ultrafilter 2 months Green Between 1 month and 2 months Yellow 1 month Red A replacement alarm will...

Страница 35: ...ulb REPLACE ULTRAFILTER There is a short cut to the instructions for replacing the primary consumables used on the SYSTEM On the main home screen each tile will show the icon of the consumable and the...

Страница 36: ...The screens below provide the details on the replacement instructions for each of the consumable 34 CONSUMABLE REPLACEMENT...

Страница 37: ...not correctly engaged in the system Once the cartridge is in place the user can proceed to reset the system Leak Detection The system comes equipped with a leak detection sensor in the back left side...

Страница 38: ...f the ClO2 SANITIZATION KIT The sanitization kit includes the following Sanitization Cartridge Jumper Tube Assembly for Dual Pack Mechanism Low Range Chlorine Dioxide Test Strips High Range Chlorine D...

Страница 39: ...g tab snaps into position It will be necessary to exert downward pressure on the inner U frame to make this connection Insert the other side of the bypass tube until the locking tab snaps into positio...

Страница 40: ...lace the other end in a drain NOTE Insert the tubing directly into the drain if possible to minimize odors In screen 5 pressing the Start Cycle which will initiate the 45 minute sanitization process T...

Страница 41: ...gloves take an additional water sample from the drain tubing into a small clean container as above and use the blue vial low range test strips to confirm 10 ppm of chlorine If a greater amount is pres...

Страница 42: ...gs and discarding In this case no additional precautions are required If emptying replace orange plugs before discarding After the Sanitization is complete replace all of the o rings supplied with the...

Страница 43: ...s and is clogged Replace the cartridge s Air trapped in the system Refer to symptom Air is getting trapped in system Defective inlet solenoid valve or dispense solenoid valve Have unit serviced by an...

Страница 44: ...nfiguration settings High cycle times lead to premature bulb failure Change recirculation settings to 10 minutes on 14 minutes off Bad ballast Replace ballast Plug bulb plug not seated Confirm bulb co...

Страница 45: ...05 micron filter is bound with air WB WG Series Bleed the filter by opening the bleed valve and allowing water to flow until all air is expelled Filter Pack Error Cartridge not aligned Reinstall cart...

Страница 46: ...60Hz WC311UVTR Remote Dispense Configuration with UV Oxidation Lamp with TOC Monitor 220V 50Hz WB301UFB Benchtop with Ultrafiltration module 120V 60Hz WB311UFB Benchtop with Ultrafiltration module 22...

Страница 47: ...nal endotoxin filter 1 4 MNPT ARI PF007105 Ultrafilter 3 8 Quick Disconnecting Fitting ARI HPA016 UV Bulb 254 185nm TOC Destruct ARI HPA017 Sanitization Kit includes cartridges test strips and gloves...

Страница 48: ...Valve Teflon Diaphragm Seal 24V 14 ARI 1280051 Back Up Battery 15 ARI 1500002 Touch Screen Display Module Preprogramed 16 ARI 1500008 250 mAmp Fuse 17 ARI 1280053 24 V Power Fuse 1 6A 18 ARI 1500018...

Страница 49: ...47 DIMENSIONAL DRAWINGS...

Страница 50: ...48 DIMENSIONAL DRAWINGS...

Страница 51: ...49 PRE INSTALLATION CHECKLIST...

Страница 52: ...s This warranty does not apply to equipment or parts which fail because of abuse accident alteration misuse erosion improper installation or improper replacement of a repaired item The buyer assumes a...

Страница 53: ...as purchased or Yamato Scientific s sales office Check following items before contact Model Name of Product Serial Number Purchase Date Issue as detailed as possible Responsibility Please follow instr...