[email protected]
Movil:959440045
133
8 Technical Reference
8.7 Interface description
Safety stop means:
The machine must be stopped in the quickest and
safest way due to vibrations or process reasons.
Comply to following conditions:
x
The bowl must be kept filled.
x
The machine must not be restarted before the
reason for the Safety stop has been
investigated and action has been taken.
In case of emergency condition in the plant, the
machine must be stopped in a way that is
described in EN 418.
8.7.2
Component description and
signal processing
Separator motor 701
The separator is equipped with a 3-phase DOL-
started (direct on line) motor. The separator can
also be started by a Y/D starter, but then the time
in Y-position must be maximized to 5 seconds.
Cover interlocking switch 760
(option)
The cover of the separator is equipped with an
interlocking switch. When the cover is closed the
interlocking circuit in the starter control is closed
and the separator could be started.
Signal processing:
The circuit is closed when the collecting cover of
the separator is closed.
The interlocking switch should be connected so
that starting of the motor is prevented when the
separator collecting hood is not closed.
www.fdm.com.pe
Содержание 881145-09-01/7
Страница 6: ...ventas fdm com pe fdmsac gmail com Movil 959440045 6 www fdm com pe...
Страница 30: ...ventas fdm com pe fdmsac gmail com Movil 959440045 3 5 Definitions 3 Separator Basics 30 www fdm com pe...
Страница 122: ...ventas fdm com pe fdmsac gmail com Movil 959440045 8 2 Technical data 8 Technical Reference 122 www fdm com pe...
Страница 172: ...ventas fdm com pe fdmsac gmail com Movil 959440045 172 www fdm com pe...
Страница 174: ...ventas fdm com pe fdmsac gmail com Movil 959440045 174 www fdm com pe...
Страница 178: ...ventas fdm com pe fdmsac gmail com Movil 959440045 178 www fdm com pe...