5.3.11 Top bearing springs
Weakened or broken buffer springs may give rise
to machine vibration (rough bowl running).
The condition (stiffness) of a spring can hardly be
determined without using special testing
equipment. So, an estimation of the spring
condition must be based on the knowledge of the
machine run before the overhaul. It is
recommended, however, to replace all the springs
at the annual overhaul.
In case of a sudden spring fracture, all springs
should be replaced even when only one spring
has broken.
5.3.12 Ball bearing housing
x
Defective contact surfaces for the buffers on
the ball bearing housing may give rise to
machine vibration (rough bowl running).
Examine the contact surface for the buffers (1) on
the ball bearing housing (3). In case of defects
(indentations deeper than 0,1 mm) replace the
housing as well as buffers and springs.
G
0
5930
11
1. Radial buffer
2. Buffer spring
3. Ball bearing housing
www.fdm.com.pe
Содержание 881145-09-01/7
Страница 6: ...ventas fdm com pe fdmsac gmail com Movil 959440045 6 www fdm com pe...
Страница 30: ...ventas fdm com pe fdmsac gmail com Movil 959440045 3 5 Definitions 3 Separator Basics 30 www fdm com pe...
Страница 122: ...ventas fdm com pe fdmsac gmail com Movil 959440045 8 2 Technical data 8 Technical Reference 122 www fdm com pe...
Страница 172: ...ventas fdm com pe fdmsac gmail com Movil 959440045 172 www fdm com pe...
Страница 174: ...ventas fdm com pe fdmsac gmail com Movil 959440045 174 www fdm com pe...
Страница 178: ...ventas fdm com pe fdmsac gmail com Movil 959440045 178 www fdm com pe...