DIP SWITCH 1: LINK MODE
RUNTIME – LINK:
OFF => ON => OFF:
Activate/deactivate Link. Toggle once to activate, toggle again to deactivate. Link will also
exit on successful completion or will auto-exit after 60 seconds (default).
Link can be used in conjunction with Q-Sys to assign station ID, static IP/Port and Q-Sys feedback information to
the V-Com. In a sense, this pairs the V-Com with a specific Q-Sys Core.
When the Link mode is active, LEDs will illuminate one at a time in a sequential chasing pattern.
DIP SWITCH 2: FIRMWARE UPDATE MODE / RESET FACTORY DEFAULTS
POWER UP – FIRMWARE UPDATE MODE:
ON:
Enter Firmware Update mode. In this mode of operation, V-Com disregards all its settings and the rest of
the DIP switches and uses a default IP of 192.168.0.254. Web server serves up Firmware Update page. For a
detailed explanation on Updating V-Com firmware, see the Firmware Update section.
To exit Firmware Update Mode, return the switch to OFF position and perform a power cycle.
OFF:
Default state of the switch for normal operation.
NOTE: It’s advised to use AMI Terminal to invoke the firmware update. The V-Com will enter the firmware
update mode on the last known IP instead of fixed 192.168.0.254
RUNTIME – LOAD FACTORY DEFAULTS (IN NORMAL OPERATION MODE ONLY):
OFF => ON => OFF:
Perform factory defaults. All LEDs will light up solid RED for a few seconds, then V-Com
will perform reset to defaults. Any stored settings will be erased from non-volatile memory and restored to their
factory defaults. This affects Dante settings as well.