background image

Provisioning Access Points

19

Chapter 2

z

TFTP time out—If the OmniAccess AP60/61 cannot locate an OmniAccess 
Wireless LAN Switch on its network port, the following type of output is 
repeatedly displayed:

Press <Control-C> to interrupt this process and access the 

apboot

 prompt.

Once the apboot prompt is displayed, perform provisioning as described in the 
next section.

Loading FLASH image... 
Verifying checksum... failed!
BOOTP broadcast 1
DHCP IP address:   10.1.2.250
DHCP subnet mask:  255.255.255.0
DHCP def gateway:  10.1.2.1
DHCP DNS server:   10.1.1.2
DHCP DNS domain:   Alcatelnetworks.com
DHCP Alcatel server: 10.1.2.11
Loading elf file: 10.1.2.11:mips.ari
Loading: T T T T T T T T T
Retry count exceeded; starting again

Содержание OmniAccess AP60

Страница 1: ...i OmniAccess AP60 61 Wireless Access Point Installation Guide TM ...

Страница 2: ...ated in the USA Trademarks OmniAccess AP60 OmniAccess AP61 OmniAccess 6000 OmniAccess 4324 OmniAccess 4304 OmniAccess 4308 and AOS W are trademarks of Alcatel in the United States and certain other countries The K Lock design is a registered trademark of the Kensington Technology Group in the United States and certain other countries Any other trademarks appearing in this manual are owned by their...

Страница 3: ... Provisioning 15 Requirements 15 Connecting the Console Terminal 16 Console Access to the AP 16 Setting OmniAccess AP60 61 Parameters 20 Chapter 3 AP Deployment 25 Mounting the OmniAccess AP60 61 25 OmniAccess AP60 Detachable Antennas 26 Free Standing Placement 28 Using the Built In Mounting Slots 30 Using the Optional Mounting Kits 32 Connecting Required Cables 32 Selecting an FE Cable 32 Connect...

Страница 4: ... LAN Switch 39 Direct Terminal Connection 40 Remote Telnet Connection 41 AP Support 42 Access Levels 42 User Commands 42 Privileged Commands 42 Appendix C Product Specifications 43 Compliance 43 Certifications 46 Product Features 47 Ethernet Compatibility 47 Radio Characteristics 47 Power Over Ethernet 48 Disposal of AP60 61 48 Physical Description 48 Package Contents 48 Optional Items 49 OmniAcce...

Страница 5: ...less network devices fixed portable or mobile computers with IEEE 802 11a or IEEE 802 11b g wireless adapters and the wired LAN As a wireless Air Monitor AM a feature unique to Alcatel products the OmniAccess AP60 61 enhances wireless networks by collecting statistics monitoring traffic detecting intrusions enforcing security policies balancing wireless traffic load self healing coverage gaps and ...

Страница 6: ...OmniAccess AP60 61 Installation Guide 2 Part 031643 00 Rev 01 June 2005 Front View FIGURE 1 1 OmniAccess AP60 61 Front View 1 2 3 4 5 A B C B A ...

Страница 7: ...rectional antennas Indicator LEDs During operation the OmniAccess AP60 61 LEDs provide the following information NOTE LEDs on the Wireless LAN Switch provide additional status and secu rity information about connected APs See the Alcatel AOS W User Guide for more information TABLE 1 1 OmniAccess AP60 61 LEDs LED State Description PWR Off The device is off no power Green Solid The device is powered...

Страница 8: ...ng the device Do not allow these vents to be obstructed by mounting equipment network cables or any other material FE Port This port attaches the OmniAccess AP60 61 to a 10Base T 100Base TX twisted pair Ethernet LAN segment This port also supports Serial and Power Over Ethernet SPOE See Appendix A for port and cable specifications 3 4 ...

Страница 9: ...ocket This socket is used to connect the optional AC power adapter not included If POE is being used to supply power to the OmniAccess AP60 61 the power adapter is not necessary Back View FIGURE 1 2 OmniAccess AP60 61 Back View 5 1 3 2 4 ...

Страница 10: ...rial Fold Out Stand This fold out stand allows the OmniAccess AP60 61 to be stood upright on a table or shelf Kensington Security Slot This slot is compatible with a Kensington MicroSaver Security Cable not included which can be used to prevent the unauthorized removal of the OmniAccess AP60 61 from its installed location To secure the OmniAccess AP60 61 wrap a security cable around an immovable o...

Страница 11: ...mniAccess AP with initial settings that allow it to locate the host OmniAccess Wireless LAN Switch Depending on the network topology and services AP provisioning can be performed manually for each AP or plug and play for batches of APs AP provisioning is discussed in Chapter 2 3 AP Deployment Once provisioned the AP can be physically installed at its intended place of operation AP deployment is co...

Страница 12: ...OmniAccess AP60 61 Installation Guide 8 Part 031643 00 Rev 01 June 2005 ...

Страница 13: ...ovisioning provides the AP with initial network settings that allow it to locate the host OmniAccess Wireless LAN Switch The following provisioning methods listed in the order of preference recommended by Alcatel are available z Plug and Play Also known as the Alcatel Discovery Protocol This is the easiest method for AP provisioning With plug and play OmniAccess APs can be connected to the network...

Страница 14: ...ge z It discovers the IP address of the master OmniAccess Wireless LAN switch in the network from which the AP can download its configuration The address of the TFTP server that ADP discovers is the equivalent of the BOOTROM environment variable serverip The IP address of the OmniAccess master switch is the equivalent of the environment variable master ADP can discover these values using DHCP or b...

Страница 15: ... on the same broadcast domain as the AP or an IP Helper must be configured to direct the broadcast ADP packets to the OmniAccess Wireless LAN switch Once these discovery prerequisites are met the switch will respond to APs with the IP address of the Master OmniAccess switch The APs can then obtain their image and configuration To enable ADP on an OmniAccess Wireless LAN switch enter 6000 config ad...

Страница 16: ...ng tab is selected by default FIGURE 2 1 Provisioning Tab 2 Configure the APs Subnet and Netmask This is the subnet from which the AP gets an IP during provisioning This is not the IP address the AP will use when deployed 3 Select the Port or Port range for provisioning To set the Port Range select the first and the last ports of your range All the ports in between are automatically selected Ports...

Страница 17: ... mandatory for all detachable antenna models as the AP will not will bring up its radio interface or function as an AP without it Complete specifying Master Discovery and IP Settings and click Apply 6 Plug the AP into one of the ports configured for provisioning If your AP is already plugged into the port unplug it and plug it in again If AP is connected through POE enter in interface mode no poe ...

Страница 18: ...U Unprovisioned to In Progress to P Provisioned NOTE Check that the configured parameters are reflected in the AP list entry NOTE Alcatel recommends that you provision each AP for a unique location as suggested by site sur vey planning Label each AP with this location information and place the AP in its proper location Failure to place APs in the location for which they were provisioned will reduc...

Страница 19: ...rated at 100 240 V 50 60 Hz or z The OmniAccess AP60 61 FE port connected to an OmniAccess 4304 OmniAccess 4308 OmniAccess 4324 or OmniAccess 6000 Wireless LAN switch that supports IEEE 802 3af Power Over Ethernet POE via a 4 or 8 conductor Category 5 UTP straight through FE cable 1 NOTE Only IEEE 802 3af Power Over Ethernet is supported for manual provisioning Inline or midspan POE devices requir...

Страница 20: ... POE from an OmniAccess Wireless LAN switch FIGURE 2 3 OmniAccess AP60 61 Console Topologies NOTE The LAN connections are optional unless POE is used to power the AP Console Access to the AP FIGURE 2 4 Connecting Directly to the AP ONSOLE ONNECTION VIA NETWORKING CLOSET ONSOLE ONNECTION VIA DIRECT ACCESS TO 0 EPLOYED OCATION ONSOLE 4ERMINAL 3ERIAL REAKOUT 3ERIAL REAKOUT ONSOLE 4ERMINAL RUBA 0 RUBA...

Страница 21: ...stalled in an air handling space as described in NEC 2002 Article 300 22 C POE must be used instead of a power outlet If local regulations and practices permit connect the optional AC power adapter not included to the DC power socket on the rear panel of the OmniAccess AP60 61 and plug it into an appropriate power outlet NOTE The indicator LEDs on the OmniAccess AP60 61 will remain dark during thi...

Страница 22: ...toboot countdown The countdown prompt allows you to interrupt the normal startup process and access the apboot prompt where provisioning is performed To access the apboot prompt press any key such as Enter before the timer expires If the countdown expires before you can interrupt it turn the device off and then back on TABLE 2 1 Console Terminal Settings Baud Rate Data Bits Parity Stop Bits Flow C...

Страница 23: ...access the apboot prompt Once the apboot prompt is displayed perform provisioning as described in the next section Loading FLASH image Verifying checksum failed BOOTP broadcast 1 DHCP IP address 10 1 2 250 DHCP subnet mask 255 255 255 0 DHCP def gateway 10 1 2 1 DHCP DNS server 10 1 1 2 DHCP DNS domain Alcatelnetworks com DHCP Alcatel server 10 1 2 11 Loading elf file 10 1 2 11 mips ari Loading T ...

Страница 24: ... LAN Switch Unless your system has been previously configured for different set tings you can skip to Step 2 Otherwise if your system was previously configured for a different setup manually set the servername environment variable to the default host name NOTE The master and serverip environment variables also affect how AP source files are selected and should be cleared when using this approach T...

Страница 25: ...erwise configure the AP with a static IP address using the following commands 3 Set the location for the specific AP if necessary Location settings depend on how much control you want over configuring logical groups of APs in the future z Default Locations If you wish all APs treated as a single entity for configuration and accounting purposes you can use the default location profile 255 255 65535...

Страница 26: ... the Alcatel RF Plan User s Guide If you prefer to enter the location data manually record the location ID you set for each access point and air monitor along with the following Building Number A unique number 1 254 is required for each building in your campus Floor Number Within any building a unique number 1 254 is required for each floor Device Number Within any floor a unique number 1 65534 is...

Страница 27: ...3 Chapter 2 4 Save the configuration and reboot the OmniAccess AP60 61 Once the OmniAccess AP60 61 boots disconnect it and mount it in its intended service location see Provisioning Access Points on page 25 apboot save apboot boot ...

Страница 28: ...OmniAccess AP60 61 Installation Guide 24 Part 031643 00 Rev 01 June 2005 ...

Страница 29: ...luding the interconnected equipment s associated LAN connections When using an external antenna 5 150 to 5 250 MHz are blocked Select a location as close as possible to the center of the intended coverage area If necessary use the Alcatel RF Plan site survey tool to determine the optimum locations for your access points and air monitors The service location should be free from obstructions or obvi...

Страница 30: ...antennas which vary OmniAccess AP60 Detachable Antennas Before deploying the OmniAccess AP60 attach the appropriate antennas not included The antenna connections should be tightened by hand to avoid overtightening The OmniAccess AP60 has dual Reverse Polarity SMA RP SMA female antenna connectors that accept a variety of high gain detachable antennas See Table 3 1 for the list of FCC approved anten...

Страница 31: ...ctional Antenna Indoor Swivel Connector 5 Nearson T614AH 2 4 5 5 X S 2 4Ghz 802 11B G AP ANT 2 High Gain Omni Directional Cylindrical Indoor with RP SMA Connector 6 Centurion IG2450 RPS MA AP ANT 3 High Gain Bi Directional Patch Antenna Indoor with RP SMA Connector 5 Centurion IB2450 RPS MA AP ANT 4 High Gain Directional Patch Antenna Indoor with RP SMA Connector 9 Centurion ID240 RPSM A CAF94379 ...

Страница 32: ...gh Gain Omni Directional Cylindrical Indoor Outdoor with RP SMA Connector 5 Cushcraft S2403BPX3 6RSM 5Ghz 802 11A AP ANT 10 High Gain Omni Directional Cylindrical Indoor Outdoor with RP SMA Connector 5 5 Cushcraft S5153WBPX 36RSM AP ANT 11 Down Tilt Omni Directional Patch Antenna Indoor with RP SMA Connector 3 5 Cushcraft SQ5153WP3 6RSM AP ANT 12 High Gain Directional Patch Antenna Indoor Outdoor ...

Страница 33: ...e antennas For best performance swivel the individual antennas OmniAccess AP60 or antenna array OmniAccess AP61 so that they are oriented vertically Once mounting is complete connect the required cables see instructions on page 32 CAUTION Do not place the OmniAccess AP60 61 in any place where it could fall on people or equipment For more secure installation use one of the optional mounting kits ...

Страница 34: ...Specifications If attaching the device to drywall we recommend using appropriate wall anchors not included as shown in Figure 3 4 on page 31 CAUTION Do not use the mounting slots to hang the OmniAccess AP60 61 from the ceiling sideways or in any place where it could fall on people or equipment For more secure installation use one of the optional mounting kits Screw Nail Positions fastened to wall ...

Страница 35: ... use a Kensington MicroSaver Security Cable not included Wrap the security cable around an immovable object insert the cable s lock into the Kensington Security Slot on the back of the OmniAccess AP60 61 and turn the key 4 Orient the antennas For best performance swivel the individual antennas OmniAccess AP60 or antenna array OmniAccess AP61 so that they are oriented vertically see Figure 3 1 on p...

Страница 36: ...rts Serial and Power Over Ethernet SPOE use an 8 conductor Category 5 UTP straight through FE cable The OmniAccess AP6000 with Line Card OAW LC 2G 24FP the OmniAccess 4324 the OmniAccess 4304 and the OmniAccess 4308 support SPOE z POE If the connecting device supports only Power Over Ethernet POE use a 4 or 8 conductor Category 5 UTP straight through FE cable z Network Only If the connecting devic...

Страница 37: ...rough cable must connect the Omni Access AP60 61 directly to the powering device without any intervening hubs routers or other net working equipment 3 Connect power if necessary The OmniAccess AP60 61 can receive electrical power using the following options z POE If connecting the OmniAccess AP60 61 to a device that supplies IEEE 802 3af compliant POE no additional power connection is necessary z ...

Страница 38: ...tices permit connect the optional AC power adapter not included to the DC power socket on the OmniAccess AP60 61 and plug it into an appropriate power outlet CAUTION To prevent personal injury or damage to equipment use only the AC power adapter certified for this device in the country where it is used ...

Страница 39: ...324 the OmniAccess 4304 and the OmniAccess 4308 support SPOE z If the connecting device supports only Power Over Ethernet POE including IEEE 802 3af POE as well as inline or mid span POE devices use an 8 or 4 conductor Category 5 UTP straight through FE cable with male RJ 45 connectors z If the connecting device does not support Serial or POE use a 4 or 8 conductor Category 5 UTP FE cable with mal...

Страница 40: ...akout adapter is used to separate the serial communications lines from the OmniAccess AP60 61 FE SPOE port This allows the administrator to connect a local serial console directly to the AP and access the apboot prompt for manual provisioning The serial breakout adapter pin outs are shown in Figure A 2 FIGURE A 2 Alcatel Serial Breakout Adapter RJ 45 Male To Network Pin Out 1 2 3 4 5 6 7 8 ETH Tx ...

Страница 41: ...ecting FE cable should be suitable under NEC Article 800 50 and marked accordingly for use in plenums and air handling spaces with regard to smoke propagation such as CL2 P CL3 P MPP or CMP Install cables in accordance with all applicable local regulations and practices To Network Specifications The RJ 45 connector labeled To Network attaches to an FE LAN segment This connection is optional unless...

Страница 42: ...OE devices will not work with the Alcatel serial breakout adapter The maximum length for FE cables is 100 meters 325 feet The OmniAccess AP60 61 and serial breakout adapter are plenum rated When is installed in an air handling space as described in NEC 2002 Article 300 22 C the connecting FE cable should be suitable under NEC Article 800 50 and marked accordingly for use in plenums and air handlin...

Страница 43: ...the AP serial console port or through the Wireless LAN switch using the Serial Over Ethernet SOE interface or using Telnet from a remote management station Direct SPOE Connection to Wireless LAN Switch This method requires that the OmniAccess AP60 61 is connected directly to an SPOE compatible network port on the Wireless LAN Switch see Connecting Required Cables on page 32 1 Telnet to the Wireles...

Страница 44: ...s AP60 61 is connected to a compatible serial console using the Alcatel serial breakout adapter see Connecting the Console Terminal on page 16 1 Set up your local terminal This procedure requires a terminal or computer running terminal emulation software with the following settings 2 Establish console communication Press Enter a few times to establish communication between the OmniAccess AP60 61 a...

Страница 45: ...ch CLI using the admin account access the configuration config prompt and issue the following commands Using Telnet to Connect Use a Telnet client on your management workstation to connect to the OmniAccess AP60 61 s individual IP address The connection command may vary depending on the specific software used but commonly appears as follows When the connection is established the AP support prompt ...

Страница 46: ...e privileged access level is available only after the AP has successfully booted and synchronized with Wireless LAN switch User Commands z ping host IP address Verify IP connectivity between the AP and the host address z route Display the contents of the AP route table z ifconfig Display the AP s IP address settings z enable privileged password Access the AP Support privileged mode Privileged Comm...

Страница 47: ...y to cause harmful interference in which case the user will be required to correct the interference at their own expense Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This product complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not ca...

Страница 48: ... interference with and or damage this device Industry Canada Class A This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Department of Communications Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux apparei...

Страница 49: ...98 providing the presumption of compliance to the European Union s Medical Device Directive 93 42 EEC The limits are designed to provide reasonable protection against harmful interference in a typical medical installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instructions may cause harmful interferen...

Страница 50: ...11 73 23 ECC The CE approval mark on back of the product indicates that it meets European Directives 73 23 EEC and 89 336 EEC R TTE Directive ETS EN 300 328 ETS EN 301 489 ETS EN 301 893 Medical Directive EN 60601 1 1 EN 60601 1 2 Safety UL Listed UL60950 UL Listed Canadian Electrical Code CSA 22 2 No 60950 EN60950 IEC60950 National Electrical Code Section 300 22 C Canadian Electrical Code Part 1 ...

Страница 51: ...Base TX twisted pair wiring The device appears as an Ethernet node and performs a routing function by moving packets between the wired LAN and remote workstations on the wireless infrastructure Radio Characteristics The OmniAccess AP60 61 can be configured to support IEEE 802 11a or IEEE 802 11b g operation as an AP and supports both IEEE 802 11a and IEEE 802 11b g operation as an AM z 802 11a pro...

Страница 52: ... or undesirable to wire for electricity The OmniAccess AP60 61 also supports inline and midspan POE devices for normal operation Inline power is POE that is integrated into FE ports and provides POE directly to devices Non POE ports can have POE added by means of a mid span device that provides POE The non POE port is connected to a mid span POE port and this mid span port is connected to the devi...

Страница 53: ... VDC 3 A and power cord z Serial breakout adapter for direct access to the AP console z Mounting kit modular cradle for walls and suspended ceilings Check with your Alcatel sales representative for the availability of optional items The following specifications apply to the OmniAccess AP60 and OmniAccess AP61 Wireless Access Points OmniAccess AP 60 Access Point FIGURE C 1 Part Number AP 60 ...

Страница 54: ...iddle band 4 channels z 5 725 5 825Ghz higher band 4 channels z 2 4 2 483Ghz US Canada ETSI z 2 4 2 497Ghz Japan Complete country list available at http www alcatel com enterprise z 2 412 2 462Ghz US Canada z 2 412 2 472Ghz ETSI z 2 412 2 484Ghz Japan Complete country list available at http www alcatel com enterprise Radio Technology Orthogonal Frequency Division Multiplexing OFDM Direct Sequence ...

Страница 55: ...nterprise z US Canada 11 z ETSI 13 z Japan 13 Complete country list available at http http www alcatel com enterprise z US Canada 11 z ETSI 13 z Japan 13 Complete country list available at http http www alcatel com enterprise Data Rates 6 9 12 18 24 36 48 54 Mbps per channel 1 2 5 5 11 Mbps per channel 6 9 12 18 24 36 48 54 Mbps per channel TABLE C 1 AP 60 802 11 Specifications Continued Descripti...

Страница 56: ...SID Radio Type Encryption Support AP and Switch 40bit 64bit 128bit 152bit WEP TKIP AES Physical HxWxD z 159 x 99 x 31 mm 6 26 x 3 90 x 1 22 ina z Weight 198 grams 7 oz Interfaces Electrical z 1 x 10 100 Base TX auto sensing Ethernet RJ 45 Interface Auto sensing MDI MDX z Serial and Power Over Ethernet 48V DC 200mA Power Over Ethernet 802 3af compliant z 1 x 5V DC Power Interface Interfaces Mechani...

Страница 57: ...put Power 100 mW maximum or lower as configured on the OmniAccess Wireless LAN Switch to comply with local regulatory requirements Operating Humidity Storage Humidity Humidity 30 to 75 non condensing 8000 feet 10 C 40 C Humidity 10 to 85 non condensing 8000 feet 25 C 55 C Standards Compliance z Ethernet IEEE 802 3 IEEE 802 3u z Power Over Ethernet IEEE 802 3af z Wireless IEEE 802 11a b g Mains Con...

Страница 58: ...2 EN55024 89 336 EEC z ETS 300 328 89 336 EEC ETS 301 489 89 336 EEC z ETS 301 893 z AS NZS 3548 Class A Safety Compliance z CSA NTRL CSA 22 2 No 950 UL 1950 z EN60950 TÜV GS IEC60950 CB z IEC 60601 1 1995 z EN 60601 1 2 1997 Model of Operation z As defined by IEC 60601 1 this unit is considered Continuous Operation equipment a Measurements indicate only the Access Point chassis Size and weight do...

Страница 59: ...Product Specifications 55 Appendix C OmniAccess AP 61 Access Point FIGURE 3 2 Part Number AP 61 ...

Страница 60: ...a ETSI z 2 4 2 497Ghz Japan Complete country list available at http http www alcatel com enterprise z 2 412 2 462Ghz US Canada z 2 412 2 472Ghz ETSI z 2 412 2 484Ghz Japan Complete country list available at http www alcatel com enterprise Radio Technology Orthogonal Frequency Division Multiplexing OFDM Direct Sequence Spread Spectrum DSSS Orthogonal Frequency Division Multiplexing OFDM Modulation ...

Страница 61: ...z Japan 13 Complete country list available at http www alcatel com enterprise z US Canada 11 z ETSI 13 z Japan 13 Complete country list available at http www alcatel com enterprise Data Rates 6 9 12 18 24 36 48 54 Mbps per channel 1 2 5 5 11 Mbps per channel 6 9 12 18 24 36 48 54 Mbps per channel TABLE 3 3 AP 61 802 11 Specifications Continued Description 802 11a 802 11b 802 11g ...

Страница 62: ... z Network Wide AP Management via CLI WEB GUI SNMPv3 z Access Point Profiles Management by Geographical Location BSSID Radio Type Encryption Support AP and Switch 40bit 64bit 128bit 152bit WEP TKIP AES Physical HxWxD z Antenna up stand closed 216 x 99 x 31 mm 8 50 x 3 90 x 1 22 ina z Antenna up stand open 209 x 99 x 74 mm 8 23 x 3 90 x 2 91 in z Antenna 90o stand closed 159 x 99 x 71 mm 6 26 x 3 9...

Страница 63: ...hernet link status Activity Wireless LAN Activity Power z Optional AC Power Adapter Input 100 240 AC 50 60 Hz z Access Point Input 5 VDC 3 A AC adapter or 48 VDC 200 mA POE Power Requirements z 5V DC 2A supplied externally via optional AC adapter kit z 48V DC 200mA Power Over Ethernet 802 3af compliant z Auto sensing externally supplied AC power or Power Over Ethernet Output Power 100 mW maximum o...

Страница 64: ...210 CAN z VCCI Class A z EN 61000 3 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 z EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 z EN 55022 EN55024 89 336 EEC z ETS 300 328 89 336 EEC ETS 301 489 89 336 EEC z ETS 301 893 z AS NZS 3548 Class A Safety Compliance z CSA NTRL CSA 22 2 No 950 UL 1950 z EN60950 TÜV GS IEC60950 CB z IEC 60601 1 1995 z EN 60601 1 2 1997 a Measurements indicate only the Ac...

Страница 65: ...ick Start Guide z OmniAccess AP60 61 Wireless Access Point Installation Guide this docu ment z Alcatel AOS W User Guide z Alcatel AOS W Reference Guide z Alcatel Wireless LAN Switch installation guide For the current versions of these manuals or to obtain the latest product release notes visit the support section of the Alcatel Web site see page 63 ...

Страница 66: ...ples this bold font depicts text that the user must type exactly as shown Arguments In the command examples italicized text within angle brackets represents items that the user should replace with information appropriate to their specific situation For example send text message In this example the user would type send at the system prompt exactly as shown followed by the text of the message they w...

Страница 67: ...ainst electrical shock is required This symbol indicates that a danger to personal safety exists Indicates caution is required Failure to heed these cautions may result in damaged equipment or loss of data TABLE 3 5 Text Conventions Continued z Main Site http www alcatel com z Support http www alcatel com enterprise z Main US Canada 800 995 2612 z Main Outside US 818 880 3500 ...

Страница 68: ...OmniAccess AP60 61 Installation Guide 64 Part 031643 00 Rev 01 June 2005 ...