background image

Conduit

®

AP

MTCAP2-L4E1-868-002 and MTCAP2-868-002 User
Guide

Содержание Conduit AP MTCAP-868-002A

Страница 1: ...Conduit AP MTCAP2 L4E1 868 002 and MTCAP2 868 002 User Guide ...

Страница 2: ... sole risk and liability MULTITECH DOES NOT WARRANT THAT THE TRANSMISSION OF DATA BY A PRODUCT OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE UNINTERRUPTED TIMELY SECURE OR ERROR FREE NOR DOES MULTITECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO ANY CELLULAR COMMUNICATIONS NETWORK MULTITECH WILL HAVE NO LIABILITY FOR ANY LOSSES DAMAGES OBLIGATIONS PENALTIES DEFICIENCIES LIABILITIES COSTS OR EXPENS...

Страница 3: ...nts 10 MTCAP L4E1 868 042L 10 MTCAP 868 042L 12 Chapter 3 Safety Information 13 PoE Safety 13 Warnings and Cautions 13 Power Supply Caution 13 Ethernet Ports 13 Ports Ethernet 13 General Safety 14 Handling Precautions 14 Radio Frequency RF Safety 14 Sécurité relative aux appareils à radiofréquence RF 14 Interference with Pacemakers and Other Medical Devices 15 Potential interference 15 Precautions...

Страница 4: ...tion 21 Mounting the Device 22 Chapter 8 Regulatory and Environmental 24 EMC Safety and Radio Equipment Directive RED Compliance 24 Waste Electrical and Electronic Equipment Statement 24 WEEE Directive 24 Instructions for Disposal of WEEE by Users in the European Union 24 REACH Statement 25 Registration of Substances 25 Restriction of the Use of Hazardous Substances RoHS 26 Information on HS TS Su...

Страница 5: ...rogrammable Access Point with optional PoE power internal LoRa antenna and EU UK Accessory Kit Europe MTCAP L4E1 868 002L LTE Cat 4 mLinux Programmable Access Point with optional PoE power internal LoRa antenna and EU UK Accessory Kit Europe MTCAP 868 002A mPower Programmable Access Point with optional PoE power internal LoRa antenna and EU UK Accessory Kit Europe MTCAP 868 002L mLinux Programmabl...

Страница 6: ...ardware Ships with the device and is available online 82104800L Telit LE910 AT Commands Reference Guide For L4E1 devices lists AT Commands and parameters used to communicate with your device 80502ST10950A Developer Documentation Our developer site includes information for the mLinux platform advanced mPower information and LoRa information For mLinux getting started and advanced information go to ...

Страница 7: ...SPECIFICATIONS AND HARDWARE INFORMATION Conduit AP MTCAP2 L4E1 868 002 and MTCAP2 868 002 User Guide 7 Chapter 2 Specifications and Hardware Information Dimensions ...

Страница 8: ...nical Drawings for Dimensions Chassis Type PC ABS Environment Operating Temperature1 0 C to 70 C Storage Temperature 40 C to 85 C Humidity 20 90 RH non condensing Power Requirements Operating Voltage 5Vdc 1 4A PoE Standard IEEE 802 3at PoE Input Power 38 57 Vdc LoRa ERP2 13 3 dBm ERP for low power channels maximum 14 dB 25 8 dB for high power channels maximum 27 dB Certifications and Compliance EM...

Страница 9: ...Device for details WPS Reserved for future use SIM Cellular models only Micro 3FF SIM slot Refer to Installing SIM Card for details LEDs STATUS Blinks when operating system is fully loaded LORA Lights when LoRa software is active CELL Cellular models only Lights when there is power to the radio Blinks when the SIM is registered with the carrier WIFI Reserved for future use Ethernet Link Left LED o...

Страница 10: ...ername and password requirements Note The device reboots when restoring settings For more information about commissioning mode consult the mPower Software Guide or mlinux developer resources Refer to Documentation Overview for details Power Measurements MTCAP L4E1 868 042L Note Multi Tech Systems Inc recommends that you incorporate a 10 buffer into the power source when determining product load Ma...

Страница 11: ...eep Mode Current Cellular Call Box Connection No Data OR IDLE Measure with no Radio Average Measured Current at Maximum Power TX Pulse Peak Current for no radio model Total Inrush Charge Total Inrush Charge Duration 38 VDC POE N A 61 mA 126 mA 272 mA 0 127 mC 10 6 mS 56 VDC N A 40 mA 106 mA 224 mA 0 130 mC 10 3 mS ...

Страница 12: ...mining product load Maximum Power MTCAP LoRa connection to MTXDOT running TXP 20 and at txdr 2 The MTXDOT was initialized to send packets by joining MTCAP and rapidly sending packet to the MTCAP Tx Pulse The average peak current Inrush Charge The total inrush charge at power on Average Measured Current at Maximum Power TX Pulse Peak Current for no radio model Total Inrush Charge Measured in Millic...

Страница 13: ...at compliant Type 2 Class 4 Power over Ethernet PoE Powered Devices PDs and require PoE Power Supply Equipment PSE that is 802 3at compliant with minimum 25 5W output power capability Ethernet port is not designed to be connected to a public Telecommunication PSTN or any other connection other than IEEE 802 3 2012 power over Ethernet devices Do not remove product labels Power Supply Caution CAUTIO...

Страница 14: ...ndations Different industries and businesses restrict the use of cellular devices Respect restrictions on the use of radio equipment in fuel depots chemical plants or where blasting operations are in process Follow restrictions for any environment where you operate the device Do not place the antenna outdoors Switch OFF your wireless device when in an aircraft Using portable electronic devices in ...

Страница 15: ...llular device EMI The FDA continues to monitor cellular devices for interactions with other medical devices If harmful interference occurs the FDA will assess the interference and work to resolve the problem Precautions for pacemaker wearers If EMI occurs it could affect a pacemaker in one of three ways Stop the pacemaker from delivering the stimulating pulses that regulate the heart s rhythm Caus...

Страница 16: ...alidate the warranty If the device is not working properly contact MultiTech Technical Support UL Notice UL Listed at 40 C limited by power supply UL Certification does not apply or extend to an ambient above 40 C and has not been evaluated by UL for ambient greater than 40 C UL has evaluated this device for use in ordinary locations only Installation in a vehicle or other outdoor locations has no...

Страница 17: ...ies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The label shown is not the actual size 1 MultiTech Model Identification 2 MultiTech Ordering Part Number 3 IMEI Number 4 Device Node Number 5 UUID 868...

Страница 18: ...LABELS 18 Conduit AP MTCAP2 L4E1 868 002 and MTCAP2 868 002 User Guide L4E1 002 Models ...

Страница 19: ...n the following image and slide the SIM card completely into the SIM holder Removing a SIM Card To remove the SIM card push the SIM card in The device ejects the SIM card Cabling the Device To cable the device Note If using PoE to power your device refer to Power over Ethernet PoE for additional information and skip Step 2 1 Connect the Ethernet cable to the Ethernet port on the device 2 Connect t...

Страница 20: ...g your device mPower Models If your device uses the mPower platform getting started information is in mPower Software Guide S000727 available through your model s page at https www multitech com brands multiconnect conduit ap mLinux Models If your device uses the mLinux platform getting started information is at http www multitech net developer software mlinux getting started with conduit mlinux ...

Страница 21: ...etermining Location Follow these guidelines for best performance The LoRa antenna is omnidirectional but for best results mount the device so the LoRa antenna is in a vertical position as shown in the following image Place the device as high as possible such as near the top of a wall Select a location central to all devices to be connected to this device Avoid obstructions Important Thick walls an...

Страница 22: ...oRa antenna is 31 2 mm long We recommend conducting a site survey to test the signal strength in different locations before you mount the device Mounting the Device 1 Determine where you want to mount the device 2 Mark where you want the screws to go 3 Drill holes for the screws and insert anchors 4 Place the mounting bracket and secure it with screws 5 Attach the device to the bracket and rotate ...

Страница 23: ...MOUNTING THE DEVICE Conduit AP MTCAP2 L4E1 868 002 and MTCAP2 868 002 User Guide 23 ...

Страница 24: ...nics products at the end of their useful life A sister directive ROHS Restriction of Hazardous Substances complements the WEEE Directive by banning the presence of specific hazardous substances in the products at the design phase The WEEE Directive covers all MultiTech products imported into the EU as of August 13 2005 EU based manufacturers distributors retailers and importers are obliged to fina...

Страница 25: ... of its products or packaging contain any of the Substances of Very High Concern SVHC on the REACH Candidate List in a concentration above the 0 1 by weight allowable limit The latest 197 substances restricted per the REACH Regulation were last updated January 2019 Refer to the following for the most current candidate list of substances http echa europa eu candidate list table ...

Страница 26: ...roducts do not contain the following banned chemicals1 Lead Pb 1000 PPM Mercury Hg 100 PPM Cadmium Cd 100 PPM Hexavalent Chromium Cr 6 1000 PPM Polybrominated Biphenyl PBB 1000 PPM Polybrominated Diphenyl Ethers PBDE 1000 PPM Bis 2 Ethylhexyl phthalate DEHP 1000 ppm Benzyl butyl phthalate BBP 1000 ppm Dibutyl phthalate DBP 1000 ppm Diisobutyl phthalate DIBP 1000 ppm Environmental considerations Mo...

Страница 27: ... Polybromi nated Biphenyl PBB Polybrominat ed Diphenyl Ether PBDE Printed Circuit Boards O O O O O O Resistors X O O O O O Capacitors X O O O O O Ferrite Beads O O O O O O Relays Opticals O O O O O O ICs O O O O O O Diodes Transistors O O O O O O Oscillators and Crystals X O O O O O Regulator O O O O O O Voltage Sensor O O O O O O Transformer O O O O O O Speaker O O O O O O Connectors O O O O O O ...

Страница 28: ... 的名称及含量水平方面的信息 有 有害 害 有 有毒 毒物 物质 质 元 元素 素 成 成分 分名 名称 称 铅 铅 PB 汞 汞 Hg 镉 镉 CD 六 六价 价铬 铬 CR6 多 多溴 溴联 联苯 苯 PBB 多 多溴 溴二 二苯 苯醚 醚 PBDE 印刷电路板 O O O O O O 电阻器 X O O O O O 电容器 X O O O O O 铁氧体磁环 O O O O O O 继电器 光学部件 O O O O O O ICs O O O O O O 二极管 晶体管 O O O O O O 振荡器和晶振 X O O O O O 调节器 O O O O O O 电压传感器 O O O O O O 变压器 O O O O O O 扬声器 O O O O O O 连接器 O O O O O O LEDs O O O O O O 螺丝 螺母以及其它五金件 X O O O O O 交流 直...

Страница 29: ...s substances 26 I interférence des radiofréquences 14 L labels 17 LEDs 9 LORA LED 9 M maintenance 15 mLinux 20 modem safety 14 mounting device 21 mPower software 20 P package contents 5 Ports Ethernet 13 power jack 9 power measurements 10 12 power supply 19 R radio frequency interference 14 receive sensitivity 8 remove SIM card 19 reset button 9 reset device 10 RoHS 26 S safety 13 modem 14 RF inte...

Страница 30: ...INDEX 30 Conduit AP MTCAP2 L4E1 868 002 and MTCAP2 868 002 User Guide U user responsibility 16 ...

Отзывы: