OmniAccess AP60/61: Installation Guide
38
Part 031643-00 Rev. 01
June 2005
z
Otherwise, use a 4- or 8-conductor, Category 5 UTP, FE cable with male
RJ-45 connectors. The port detects MDI/MDX and automatically adjusts for
straight-through or crossover cables.
N
OTE
—
Only IEEE 802.3af Power Over Ethernet is supported for manual provisioning. “Inline” or “mid-
span” POE devices will not work with the Alcatel serial breakout adapter.
The maximum length for FE cables is 100 meters (325 feet).
The OmniAccess AP60/61 and serial breakout adapter are plenum rated. When
is installed in an air-handling space, as described in NEC (2002) Article
300.22(C), the connecting FE cable should be suitable under NEC Article
800.50 and marked accordingly for use in plenums and air-handling spaces
with regard to smoke propagation, such as CL2-P, CL3-P, MPP or CMP.
Install cables in accordance with all applicable local regulations and practices.