OmniAccess AP60/61: Installation Guide
36
Part 031643-00 Rev. 01
June 2005
The maximum length for FE cables is 100 meters (325 feet).
When the OmniAccess AP60/61 is installed in an air-handling space, as
described in NEC (2002) Article 300.22 (C), POE is required. Also, any FE cable
installed in such spaces should be suitable under NEC Article 800.50 and
marked accordingly for use in plenums and air-handling spaces with regard to
smoke propagation, such as CL2-P, CL3-P, MPP or CMP.
Install cables in accordance with all applicable local regulations and practices.
Serial Breakout Adapter
The optional serial breakout adapter is used to separate the serial
communications lines from the OmniAccess AP60/61 FE+SPOE port. This
allows the administrator to connect a local serial console directly to the AP and
access the
apboot
prompt for manual provisioning.
The serial breakout adapter pin-outs are shown in
Figure A-2
:
F
IGURE
A-2
Alcatel Serial Breakout Adapter
RJ-45 Male "To Network" Pin-Out
1
2
3
4
5
6
7
8
ETH Tx+
(POE
negative)
ETH Tx–
(POE
negative)
ETH Rx+
(POE
positive)
ETH Rx–
(POE
positive)
Serial TxD
Serial TGND
Serial RxD
Serial RGND
RJ-45 Male "To AP" Pin-Out
1
2
3
4
5
6
7
8
ETH Rx+
(POE
negative)
ETH Rx–
(POE
negative)
ETH Tx+
(POE
positive)
ETH Tx–
(POE
positive)
RxD
TxD
SG
5
4
3
2
1
9
8
7
6
DB-9 Female Pin-Out
Input
Output
Direction
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Internal Adapter Wiring
"To AP"
"To Network"
To Console
Содержание OmniAccess AP60
Страница 1: ...i OmniAccess AP60 61 Wireless Access Point Installation Guide TM ...
Страница 12: ...OmniAccess AP60 61 Installation Guide 8 Part 031643 00 Rev 01 June 2005 ...
Страница 28: ...OmniAccess AP60 61 Installation Guide 24 Part 031643 00 Rev 01 June 2005 ...
Страница 59: ...Product Specifications 55 Appendix C OmniAccess AP 61 Access Point FIGURE 3 2 Part Number AP 61 ...
Страница 68: ...OmniAccess AP60 61 Installation Guide 64 Part 031643 00 Rev 01 June 2005 ...