Swimming Pool Heat Pump Inverboost C /
11
Note:
If automatic dosing equipment for chlorine and acidity (pH) is used, it is essential
to protect the heat pump against excessively high chemical concentrations which may
corrode the heat exchanger. For this reason, equipment of this sort must always be fitted
in the piping on the downstream side of the heat pump, and it is recommended to install
a check-valve to prevent reverse flow in the absence of water circulation.
Damage to the heat pump caused by failure to observe this instruction is not covered by
the warranty.
NOTE
5.2.
Check-valve installation
Item
Product description
1
Filter
2
Check-valve
3
Chlorinator
4
Water Pump
5
P-trap
6
Check-valve
7
In-linw Chlorinator or Brominator
1
2
3
4
5
6
7