7.4.3.
Button
and
Lock / Unlock the display:
Hold
and
for 5 seconds to lock/unlock the display.
Water temperature setting:
Press
or
to set the water temperature directly.
Parameter checking:
Press
first, then press
to check the “ User parameter from d0 to d11
Remark: d4: Frequency limitation code,
0: No frequency limit,
1: Coil pipe temperature limit,
2: Overheating or overcooling frequency limit
4 Drive Current frequency limit
8: Drive voltage frequency limit
16: Drive high temperature frequency limit.
Press
first, then press
to check/adjust the User parameter from P0 to P7
If needed, press
second, then press
or
to adjust the current parameter.
(for example: Press
first, then press
to enter parameter P7 checking, and press
second,
then press
or
to adjust the parameter P7 Inlet water temp. Correction from -9 to 9.)
NOTE: Under defrosting mode, P0=1. After defrosting finished, it will be automatic enter Normal
mode, P0=0.
Code
Condition
Scope
Remark
d0
IPM mould temperature
0-120°C
Real testing value
d1
Inlet water temp.
-9°C~99°C
Real testing value
d2
Outlet water temp.
-9°C~99°C
Real testing value
d3
Ambient temp.
-30°C~70°C
Real testing value
d4
Frequency limitation code
0,1,2,4,8,16
Real testing value
d5
Piping temp.
-30°C~70°C
Real testing value
d6
Gas discharge temperature
0°C~C5°C (125°C)
Real testing value
d7
Step of EEV
0~99
N*5
d8
Compressor running frequency
0~99Hz
Real testing value
d9
Compressor current
0~30A
Real testing value
d10
Current fan speed
0-1200 (rpm)
Real testing value
d11
Error code for last time
All error code
Code
Name
Scope
Defaul
Remark
P0
Mandatory defrosting
0-1
0
0: Default normal operation
1: mandatory defrosting.
P1
Working mode
0-1
1
1:Heating mode,
0:cooling mode,
P2
Timer on/off
0-1
0
1 Timer on/off is under function.
0 Timer on/off is out of function
(The setting of P5 and P6 won’t work)
P3
Water pump
0-1
0
1: Always running;
0: Depends on the running of compressor
P4
Current time
HH:MM
00:00
0-23:0-59
P5
Timer on
HH:MM
00:00
0-23:0-59
P6
Timer off
HH:MM
00:00
0-23:0-59
P7
Water temp. calibration
-9~9
0
Výchozí nastavení: 0