34
/ Swimming Pool Heat Pump Inverboost C
Maintenance
10.
(1) You should check the water supply system regularly to avoid the air entering the system and
occurrence of low water flow, because it would reduce the performance and reliability of HP unit.
(2) Clean your pools and filtration system regularly to avoid the damage of the unit.
(3) Only a qualified technician is authorized to operate the cooling system pressure.
(4) In another way, you should check the unit is water fully before the unit start to run again.
(5) Check the water levels before the unit start after a long break in usage.
(6) During the operation of the device, condensate may drain from the bottom, especially from the
drain hose. This is normal.
(7) For winter, it is recommended to disconnect the heat pump and leave it in a room with
above-zero temperatures, together with other technologies.
Winterization
11.
IMPORTANT:
If essential measures to prepare the heat pump for winter are not taken, the heat pump could be
damaged, which will void the warranty.
The heat pump, filtration pump, and all installed technology of the swimming pool must not be
exposed to temperatures below the freezing point. It is necessary to remove all water from this
whole system (technology), especially the heat and circulating pump, in an appropriate manner.
WE RECOMMEND DOING THE FOLLOWING:
1. Disconnect the power supply to the heat pump.
2. Close the water inlet to the heat pump: completely close valves 2 and 3 in the bypass.
3. Disconnect the connection parts of the heat pump for intake and outlet of water and allow the
water to drain from the heat pump.
4. Warning: Unscrew the water drain bolt from the bottom of the heat pump to drain the water
from the heat exchanger completely. Avoiding this step may result in the heat exchanger being
damaged – torn, which is not covered by the waranty.
5. In the winter season, it is recommended to fit the disconnected heat pump in a place where
temperatures will not fall below freezing point. Warning: always make sure that the water is fully
drained from the heat pump.
6. Loosely reconnect the connection parts for water intake and outlet to/from the heat pump in
order to avoid any pollutants being deposited in the pipes. This is only the case when you have no
possibility to store the heat pump according to item 5.