background image

Terminology Used in this Manual 

What is a 

Lock Program

?

 

A Lock Program contains the instructions that a lock uses to per-
form its various functions.  You can use the keypad to create a 
Lock Program stored within the lock.  You can also use DL-
Windows (defined below) to create a Lock Program on your com-
puter, and then transfer and store the Program in the circuitry con-
tained inside the lock itself.  The Lock Program is essentially a 
computer database file that maintains feature settings, schedules, 
audit trails, etc.  Using DL Windows, Lock Programs can be cre-
ated with default information, edited on your PC, and then sent to 
(and even received from) locks.   

 

The 

Lock Program 

consists of 4 areas:  

User Codes

Features

Time Zones

, and 

Schedules

, all defined below:   

 

What are 

User Codes

?

 

Also called 

User Access Codes

 or 

PIN No. Codes

, User Codes 

are numbers the User enters into the lock keypad to unlock the 
lock.  The User Codes are part of the Lock Program, and the Lock 
Program is stored in the lock circuitry awaiting the Users to key in 
their User Codes.   
 

What are 

Features

?

 

Your lock is designed to support several options and functions.  
Using the keypad or DL-Windows software (the 

Programmable 

Features 

window), you can select the features you wish to acti-

vate, such as if the lock will automatically adjust for Daylight Sav-
ing Time in the spring and autumn, or if the lock sounder should be 
disabled or enabled. 
 

What is a 

TimeZone

?

 

Events (recorded lock activities) can be programmed to occur at 
certain times.  It is these times (for example, “every Tuesday at 
5PM”) that are referred to as 

TimeZones

.  TimeZones can be cre-

ated manually through the keypad.  In DL-Windows, you can use 
the 

Schedule-TimeZone 

screen to create these TimeZones, and 

once created, you can link events to these TimeZones. 

 
What is a 

Schedule

?

 

Your lock can be programmed to maintain a schedule in which 
certain events can occur automatically.  For example, you can pro-
gram the lock to allow Groups of Users (with their User Codes) 
access ONLY during specific business hours.  With another exam-
ple, you can program another lock to UNLOCK at 9am, LOCK at 
noon for lunch, UNLOCK at 1pm, and LOCK again at 5pm--every 
weekday.  As you can see, many different combinations of Sched-
ules can be created to suit the needs of the Users.  First you cre-
ate 

TimeZones

 (see above).  Next you create events and link them 

to your TimeZones (also using the 

Schedule-TimeZone 

screen in 

DL-Windows).  When finished, you can view (in DL-Windows) your 
schedule in the 

Schedule View 

screen.

 

 

What is a 

User

A User is a person who is authorized to simply use or make certain 
programming changes to the lock.  This User can be anyone--from 
a one-time visitor (who will almost certainly have no authority to 
make changes) to the owner of the building in which the lock is 
installed (who will probably wish to have total authority to make 
changes).  The PDL Series locks can hold up to 2000 Users in its 
programming memory, and each User possesses a pre-defined 
level of authority--a 

Programming Level

--as to their ability to use 

or make changes to the lock.   
 

What is a 

Programming Level

?

 

The Programming Level defines the range of programming tasks a 
User is allowed to perform.  The higher the Level, the more pro-
gramming tasks the User is allowed (with Master allowing ALL 
tasks).   

 

Note:  

Since the Programming Level is closely associated with the 

type of User and their abilities, a User who holds a certain Pro-
gramming Level is sometimes referred to by their “

User Type

”. 

 

For example, 

PDL Series 

locks can hold up to 2000 Users in its 

programming memory, and each User is associated with a User 
Number (see definition of "User Number" below) and therefore a 
specific Programming Level, as follows: 

 

Master:  

Always associated with User Number 1.  Is always en-

abled and can program all functions.  (Abbreviated as 
Programming Level = M). 

Installer:  

Always associated with User Numbers 2 and 3.  Can 

program all functions except changing the Master Code.  
(Abbreviated as Programming Level = 4).

 

Manager:  

Always associated with User Numbers 4, 5, and 6.  

Can program all functions except functions relating to lock 
configuration.  (Abbreviated as Programming Level = 3). 

Supervisor:

  Always associated with User Numbers 7, 8 and 9.  

Can only program functions relating to day to day operation.  
(Abbreviated as Programming Level = 2). 

Print Only Users:

  Always associated with User Numbers 10 & 

11.  Restricted to print event logs only.  No other programming 
ability allowed.  (Abbreviated as Programming Level = 1).

 

Basic Users:  

Always associated with User Number 12 and higher 

(except 297-300).  No programming ability allowed.  Most 
Users are 

Basic Users

, who are given their own personal User 

Codes and are only allowed to simply unlock the lock when 
desired.   

 
Programming Levels are hierarchical--higher levels are allowed to 
do anything the levels below them can do.  For example, if you are 

Manager

, you are allowed to do anything that 

Supervisors

Print-

Only Users 

and 

Basic Users 

can do in addition to those tasks al-

lowed for Managers (Level 3).  

Note:  The above Programming 

Levels apply to the PDL series locks only.  For the DL2800/
DL3000 series locks, the Programming Levels are slightly dif-
ferent.  See page 8 for more information. 

 

What is the 

Minimum Required Program Level

This Programming Level abbreviation is the 

minimum 

program-

ming level required to access the particular Function.  (The higher 
the level number, the more programming tasks the User is al-
lowed, with Master allowing all tasks). 
 
In this manual, Programming Levels for the DL3500, PDL3000 and 
PDL3500 are abbreviated as follows:  

= Master, 

4

 = Installer, 

3

 = 

Manager, 

2

 = Supervisor, 

1

 = Print Only Users 

 
For the DL3000, the Master is abbreviated with an "M", and all 
other Levels are hierarchical, with higher levels being allowed to do 
anything the levels below them can do.  Therefore Level 4 is 
"higher" than level 3.  See page 8 for more information. 
 

What is a 

User Number

(

User Number 

Location Number 

User Location = Slot in Lock

User Numbers are used and are significant within each individual 
lock only.  The User Number determines the Programming Level 
for each User.  For example, PDL Series locks can hold up to 

Содержание Trilogy ETPDL

Страница 1: ...Access Control Systems with ProxCard Access WI1021C 9 06 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 Publicly traded on NASD...

Страница 2: ...ader and a real time clock calendar that automatically adjusts for Daylight Saving Time and allows for automated programming of events Features three methods of programming 1 all fea tures can be prog...

Страница 3: ...nctions see page 17 21 User Access Methods Keypad Entered User Codes see pages 12 13 16 ProxCard and ProxKey Keyfob see page 13 User Code and ProxCard For highest security see page 13 Batch Enroll Qui...

Страница 4: ...ation Double ended Mini Banana Plug Connector After you create the program in DL Windows and transfer the program from your computer to an AL DTM transfer the program from the AL DTM to the lock s via...

Страница 5: ...r lock to start working To begin programming you must first enter something called Program Mode What is Program Mode Most technical people find working with hardware easy they use tools to make fixes...

Страница 6: ...sses a pre defined level of authority a Programming Level as to their ability to use or make changes to the lock What is a Programming Level The Programming Level defines the range of programming task...

Страница 7: ...associated with User 300 User 297 does this by first entering their own User 297 User Code into the lock keypad When User 300 subsequently enters their User 300 User Code the lock al lows access for...

Страница 8: ...ser Type For example PDL Series locks can hold up to 2000 Users in its programming memory and each User is associated with a User Number see definition of User Number in the previous Terminology secti...

Страница 9: ...Mode Information If a wrong key is pressed during code entry hold any key continuously until the error sound is heard 7 short beeps this will clear the entry Re enter the key sequence again All progr...

Страница 10: ...ode to send or receive data Using DL Windows IBM COMPATABLE LAPTOP OR DESKTOP PC NOTE OBSERVE TAB DIRECTION WHEN INSERTING CABLE INTO LOCK AL PCI CABLE CONNECT TO SERIAL PORT COM 1 4 PDL3000 LOCK Scen...

Страница 11: ...battery pack 2 With battery power disconnected press and hold down for 10 seconds to ensure discharge of all ca pacitors 3 Re install the battery pack lock will sound 3 short beeps If beeps are not he...

Страница 12: ...ode to be 664433 Press 1 664433 664433 Now that the Master Code has been changed there is no need to change it again unless you want to Since you are still in Program Mode you can now proceed directly...

Страница 13: ...three times the card has been enrolled 4 Press to end the process To return to normal operation exit Program Mode see below For example you wish to enroll two ProxCards for User 14 and User 15 respec...

Страница 14: ...Security Access ProxCard User Code Test ProxCard programmed for High Security Access A ProxCard and User Code are both required for access 1 Enter the User Code for the User Number programmed for High...

Страница 15: ...gramming Functions Overview Function 48 Enable Passage Mode See page 22 Function 49 Disable Passage Mode See page 22 Function 50 Return Lock to Normal Passage Mode Schedule See page 22 Function 51 Pas...

Страница 16: ...is Keypad Code Access only Factory Default 123456 See Lock Design Overview on page 5 for more information about Master Codes 3 M USERS Lock Defaults for PDL3000 3500 ETPDL See page 8 Users added will...

Страница 17: ...rogram Mode and pressing 5 1157 008 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions 2 Service Code is a...

Страница 18: ...main 3 13 Clear All Timeout Functions This Function enabled through keypad only CLEAR FUNCTIONS Group Enable Disable Enter the functions below to Enable Disable Groups Functions 14 23 will each overri...

Страница 19: ...ssociation As per the chart on page 8 the lock s default programming from the factory associates certain User Numbers with certain Groups To override these default Group associations Function 35 manua...

Страница 20: ...d ends at 2AM on the programmed date Enter 4 1 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Defa...

Страница 21: ...xample if the clock has already been set to speed up 10 seconds per day and then is found to need an additional 10 seconds then program 20 seconds using Function 43 Example 1 Clock is losing 13 second...

Страница 22: ...ode is entered When the Pass Time expires the lock will re lock automatically Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Pass Time 4...

Страница 23: ...Figure 2 above To abort printing press any key for 3 seconds three short beeps will sound Hold the printer over the lock s infrared sensor as shown in Figure 1 and Figure 2 above For use with DL WINDO...

Страница 24: ...OUT 6 4 64 Disable Remote Input Wire a Normally Open Contact to Wires White White Momentarily close switch to unlock door to allow person to pass through door Enter the functions below to Disable Enab...

Страница 25: ...rammed relay features Subsequent relay feature pro gramming will not take effect while this feature is active Before pro gramming any other relay features press 6 8 0 0 0 to delete this feature Use Fu...

Страница 26: ...8 0 _ _ _ _ _ Day Time 81 Schedule Disable Group 3 8 1 _ _ _ _ _ Day Time 82 Schedule Disable Group 4 8 2 _ _ _ _ _ Day Time 83 Schedule Disable All Groups 8 3 _ _ _ _ _ Day Time 3 Clear All Schedule...

Страница 27: ...Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Note Do not use this feature in Residency mode Scheduled P...

Страница 28: ...of day in 24 hour format for example for 2 15 PM enter 14 15 Scheduled Relay Activation Group 1 Activated 9 1 _ _ _ _ _ Day Time 91 Relay Activation Close Time Window SCHEDULES GROUP 1 ACTIVATED 3 NO...

Страница 29: ...d within this window Group 4 members will be enabled Group 4 members will still need to enter their User Codes to enter For additional information see Group 1 Activated Features on page 30 For day ent...

Страница 30: ...To Disarm a Burglary Control Panel on page 28 If a Group 1 User does not enter their User Code during the specified window Func tions 90 91 remain inactive Function 92 and 93 allow for a window of tim...

Страница 31: ...of the alarm panel Functions 92 93 Use Function 92 and 93 see page 29 to create a window of time where if any Group 1 User Code is entered within the programmed window Group 4 Users will be enabled 1...

Страница 32: ...apply 1 Remote Input switch closed and Function 65 Remote Input enabled 2 Remote Input switch closed and Function 64 Remote Input disabled 3 Failed attempted entry 4 Disabled User or Group 5 Follow A...

Страница 33: ...mber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...

Страница 34: ...programmed Up to only 150 using AL DTM2 For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter...

Страница 35: ...LE A device that permits transfer of program data between a computer and the lock DATE Month Day and Year entered as MMDDYY DAY OF WEEK Sunday through Saturday where 1 Sunday and 7 Saturday DEFAULT De...

Страница 36: ...ll have no obligation under this warranty or otherwise if the product has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire...

Отзывы: