background image

2000 Users in its programming memory.  This memory can be 
thought of as simply a numbered list from 1 through 2000.  Each 
entry in the list is represented by a User Number.  Therefore, 

where 

a User is located in this list--their 

User Location

--is a com-

monly used description of their User Number.  Because of their 
similarities, a 

User Number

User Location 

and 

Location Number 

can be used interchangeably.  In some DL-Windows screens, the 
word "Slot" is also used.  They all mean the same thing. 

 

Since User Numbers are fixed, knowing a User Number will spec-
ify the associated Programming Level, and will in turn indicate a 
User’s programming abilities.  For example, User Number 1 is 
always the Master, who can perform all programming tasks. 

 

Programming Levels are hierarchical--higher levels are allowed to 
do anything the levels below them can do.  For example, if you 
are User 2, you are allowed to do anything that Users 3 through 
2000 can do.  The DL3000/DL3500 series locks can hold up to 
300 Users in its memory, however, the definition of a User Num-
ber is the same for these locks as well. 
 

What is a 

Group

With many lock applications, it is convenient for large numbers of 
similar Users to be grouped together.  Placing Users into Groups 
(by assigning them specific User Numbers) allows large numbers 
of Users to be controlled all at once rather than individually--
saving time and effort.  Groups are controlled via schedules, and 
a typical example involves enabling or disabling a Group at a cer-
tain time.  Default Group associations are specified in the tables 
on page 8.  For example, if you wish to add a User to Group 1, 
assign this User a User Number between 51 and 100.  These 
default Group associations can be changed if needed to allow 
Groups larger than the default number of 50 (by using keypad 
Function 35).  (See page 18 for some Group function examples). 

 

Who are 

Users 297-300

Users assigned to User Numbers 297, 298, 299 and 300 have 
special abilities, as follows: 

 

User 297:  

Quick Enable User 300

 

User 297 possesses the unique ability to enable the User Code 
associated with User 300.  User 297 does this by first entering 
their own 

User 297 User Code 

into the lock keypad.  When User 

300 subsequently enters their 

User 300 User Code

, the lock al-

lows access (for one time) and then the 

User 300 User Code 

becomes disabled. 

 

For example, you wish to allow one-time access to a temporary 
worker.  Simply enter the 

User 297 User Code 

into the lock key-

pad.  Later, when the temporary worker enters the 

User 300 

User Code 

into the lock keypad, the 

User 300 User Code 

allows 

access (for one time only) and then becomes disabled.  Later, if 
you wish to grant the temporary worker re-access, simply re-
enter the 

User 297 User Code 

and the 

User 300 User Code 

will 

be re-enabled (again for one time only).   
 

User 298:  

Quick PC Access Code

 

Entering the User Code for User 298 enables that User to send 
data to or from the lock.  Therefore, User 298 can activate what 
is the equivalent of Function 58 in Program Mode (see page 23), 
without the need to enter Program Mode nor the need to know 
the Master Code of the lock.  An AL-PCI cable with a PC is re-
quired.   
 

User 299:  

AL-DTM Code

 

This is the only User Code that will initiate data transfer with the 
AL-DTM--and without allowing the User to pass through the door 
(the User Code for User 299 is not an Access Code).  An AL-
PCI cable and an AL-DTM (first programmed by the computer 
via the 

DTM or DTM2 

screen in DL-Windows) is required. 

 

User 300:  

One-Time Only Service Code

 

This is a 

One-Time Only Service User Code 

enabled by User 

297.  For example, User Code 300 is sometimes used for guard 
tour duties.  See 

User 297:  Quick Enable User 300 

above.   

 

What is 

DL-Windows

?

 

DL-Windows is a computer program that allows you to program 
your ALARM LOCK T3 Security Lock.  You do not need DL-
Windows to program your lock, but it makes programming much 
faster and easier.  With DL-Windows, you can quickly create Lock 
Programs (programs that make the lock perform its many func-
tions) add multiple Users (who have access), add ProxCards

®

 and 

ProxKey

®

 keyfobs, retrieve event logs, and create Schedules.  The 

benefit of DL-Windows is that it allows you to set up all lock pro-
gramming in advance (on your computer), and then later send the 
information to the locks at your convenience. 

Terminology Used in this Manual (cont'd) 

Содержание Trilogy ETPDL

Страница 1: ...Access Control Systems with ProxCard Access WI1021C 9 06 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 Publicly traded on NASD...

Страница 2: ...ader and a real time clock calendar that automatically adjusts for Daylight Saving Time and allows for automated programming of events Features three methods of programming 1 all fea tures can be prog...

Страница 3: ...nctions see page 17 21 User Access Methods Keypad Entered User Codes see pages 12 13 16 ProxCard and ProxKey Keyfob see page 13 User Code and ProxCard For highest security see page 13 Batch Enroll Qui...

Страница 4: ...ation Double ended Mini Banana Plug Connector After you create the program in DL Windows and transfer the program from your computer to an AL DTM transfer the program from the AL DTM to the lock s via...

Страница 5: ...r lock to start working To begin programming you must first enter something called Program Mode What is Program Mode Most technical people find working with hardware easy they use tools to make fixes...

Страница 6: ...sses a pre defined level of authority a Programming Level as to their ability to use or make changes to the lock What is a Programming Level The Programming Level defines the range of programming task...

Страница 7: ...associated with User 300 User 297 does this by first entering their own User 297 User Code into the lock keypad When User 300 subsequently enters their User 300 User Code the lock al lows access for...

Страница 8: ...ser Type For example PDL Series locks can hold up to 2000 Users in its programming memory and each User is associated with a User Number see definition of User Number in the previous Terminology secti...

Страница 9: ...Mode Information If a wrong key is pressed during code entry hold any key continuously until the error sound is heard 7 short beeps this will clear the entry Re enter the key sequence again All progr...

Страница 10: ...ode to send or receive data Using DL Windows IBM COMPATABLE LAPTOP OR DESKTOP PC NOTE OBSERVE TAB DIRECTION WHEN INSERTING CABLE INTO LOCK AL PCI CABLE CONNECT TO SERIAL PORT COM 1 4 PDL3000 LOCK Scen...

Страница 11: ...battery pack 2 With battery power disconnected press and hold down for 10 seconds to ensure discharge of all ca pacitors 3 Re install the battery pack lock will sound 3 short beeps If beeps are not he...

Страница 12: ...ode to be 664433 Press 1 664433 664433 Now that the Master Code has been changed there is no need to change it again unless you want to Since you are still in Program Mode you can now proceed directly...

Страница 13: ...three times the card has been enrolled 4 Press to end the process To return to normal operation exit Program Mode see below For example you wish to enroll two ProxCards for User 14 and User 15 respec...

Страница 14: ...Security Access ProxCard User Code Test ProxCard programmed for High Security Access A ProxCard and User Code are both required for access 1 Enter the User Code for the User Number programmed for High...

Страница 15: ...gramming Functions Overview Function 48 Enable Passage Mode See page 22 Function 49 Disable Passage Mode See page 22 Function 50 Return Lock to Normal Passage Mode Schedule See page 22 Function 51 Pas...

Страница 16: ...is Keypad Code Access only Factory Default 123456 See Lock Design Overview on page 5 for more information about Master Codes 3 M USERS Lock Defaults for PDL3000 3500 ETPDL See page 8 Users added will...

Страница 17: ...rogram Mode and pressing 5 1157 008 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions 2 Service Code is a...

Страница 18: ...main 3 13 Clear All Timeout Functions This Function enabled through keypad only CLEAR FUNCTIONS Group Enable Disable Enter the functions below to Enable Disable Groups Functions 14 23 will each overri...

Страница 19: ...ssociation As per the chart on page 8 the lock s default programming from the factory associates certain User Numbers with certain Groups To override these default Group associations Function 35 manua...

Страница 20: ...d ends at 2AM on the programmed date Enter 4 1 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Defa...

Страница 21: ...xample if the clock has already been set to speed up 10 seconds per day and then is found to need an additional 10 seconds then program 20 seconds using Function 43 Example 1 Clock is losing 13 second...

Страница 22: ...ode is entered When the Pass Time expires the lock will re lock automatically Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Pass Time 4...

Страница 23: ...Figure 2 above To abort printing press any key for 3 seconds three short beeps will sound Hold the printer over the lock s infrared sensor as shown in Figure 1 and Figure 2 above For use with DL WINDO...

Страница 24: ...OUT 6 4 64 Disable Remote Input Wire a Normally Open Contact to Wires White White Momentarily close switch to unlock door to allow person to pass through door Enter the functions below to Disable Enab...

Страница 25: ...rammed relay features Subsequent relay feature pro gramming will not take effect while this feature is active Before pro gramming any other relay features press 6 8 0 0 0 to delete this feature Use Fu...

Страница 26: ...8 0 _ _ _ _ _ Day Time 81 Schedule Disable Group 3 8 1 _ _ _ _ _ Day Time 82 Schedule Disable Group 4 8 2 _ _ _ _ _ Day Time 83 Schedule Disable All Groups 8 3 _ _ _ _ _ Day Time 3 Clear All Schedule...

Страница 27: ...Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Note Do not use this feature in Residency mode Scheduled P...

Страница 28: ...of day in 24 hour format for example for 2 15 PM enter 14 15 Scheduled Relay Activation Group 1 Activated 9 1 _ _ _ _ _ Day Time 91 Relay Activation Close Time Window SCHEDULES GROUP 1 ACTIVATED 3 NO...

Страница 29: ...d within this window Group 4 members will be enabled Group 4 members will still need to enter their User Codes to enter For additional information see Group 1 Activated Features on page 30 For day ent...

Страница 30: ...To Disarm a Burglary Control Panel on page 28 If a Group 1 User does not enter their User Code during the specified window Func tions 90 91 remain inactive Function 92 and 93 allow for a window of tim...

Страница 31: ...of the alarm panel Functions 92 93 Use Function 92 and 93 see page 29 to create a window of time where if any Group 1 User Code is entered within the programmed window Group 4 Users will be enabled 1...

Страница 32: ...apply 1 Remote Input switch closed and Function 65 Remote Input enabled 2 Remote Input switch closed and Function 64 Remote Input disabled 3 Failed attempted entry 4 Disabled User or Group 5 Follow A...

Страница 33: ...mber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...

Страница 34: ...programmed Up to only 150 using AL DTM2 For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter...

Страница 35: ...LE A device that permits transfer of program data between a computer and the lock DATE Month Day and Year entered as MMDDYY DAY OF WEEK Sunday through Saturday where 1 Sunday and 7 Saturday DEFAULT De...

Страница 36: ...ll have no obligation under this warranty or otherwise if the product has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire...

Отзывы: