Groups and Scheduled Group 1 Examples 

 

The following examples detail the more advanced features of the PDL series locks.  Although all features and device functions can be programmed 
using the lock keypad, when programming becomes more complex you may find it easier to use DL-Windows software to program your Alarm Lock 
security lock.  For more information, contact your Alarm Lock security professional. 
 

Assign a User to Two Groups 

Create a User 101 (all Users 101-150 are members of Group 2 by default) and include User 101 in Group 3 (as well as the default Group 2). 

1.    Enter Program Mode (if not in already). 
2.    Using Function 2, create User 101 with a User Code of "789":   

Press 

;

 

2

 

;

 

1

 

0

 

1

 

;

 

7

 

8

 

9

 

:

3.    Using Function 35, make User 101 a member of Group 2 

and 

3:   

Press 

;

 

3

 

5

 

;

 

1

 

0

 

1

 

;

 

2

 

3

 

:

4.    Exit Program Mode.   

 

Note:

  See step 3 above--although User 101 is by default a member of Group 2, you must include Group 2 when using Function 35 or the 

Group 2 association will be removed. 

 

The example to add Users to Group 2 and Group 3 has been selected due to the fact that 

Group 1 Activated Functions 

require that a member 

of Group 1 enter their User Code to activate the Function, and it may become necessary to assign Users to Groups.   

 
 

Group 1 Activated Features:  Functions 88/89, 90/91 and 92/93 

Function 88 and 89 

allow for a window of time to be created where if any Group 1 User Code is entered within the programmed window, 

Passage Mode 

will be activated (the device physically unlocks, allowing passage for all).  If a Group 1 User does not enter their User Code 

during the specified window, Functions 88/89 remain inactive. 

Function 90 and 91 

allow for a window of time to be created where if any Group 1 User Code is entered within the programmed window, an 

internal 

Relay 

will be activated for 2 seconds.  This Relay can be used with a burglar alarm control panel that has a key switch disarm option.  

See 

To Disarm a Burglary Control Panel 

on page 28.  If a Group 1 User does not enter their User Code during the specified window, Func-

tions 90/91 remain inactive. 

Function 92 and 93 

allow for a window of time to be created where if any Group 1 User Code is entered within the programmed window, the 

User Codes in Group 4 

will be enabled.  If a Group 1 User does not enter their User Code during the specified window, Functions 92/93 re-

main inactive.  Companies typically use this feature to allow Group 1 Managers the ability to enable all Group 4 staff members during a cer-
tain window of time.   

 

The following examples illustrate how Functions 88-93 (see pages 27-29) can be programmed into your PDL Series lock via the keypad: 

 

Functions 88/89

:  

Use Function 88 to set an 

Open Time Window

 (during which the Group 1 User must enter their User Code), and then use 

Function 89 to set the time to close the Window.  Re-lock the door at night manually (Function 46). 

 

1.    Enter Program Mode (if not in already). 
2.    Using Function 2, create User 4 with a User Code of "456789": 

Press 

;

 

2

 

;

 

4

 

;

 

4

 

5

 

6

 

7

 

8

 

9

 

:

3.    Because User 4 does not have a default Group association, make User 4 a member of Group 1 using Function 35: 

Press 

;

 

3

 

5

 

;

 

4

 

;

 

1

 

:

4.    Use Function 88 and Function 89 (see page 27) to designate Passage Mode as being between the hours of 8:30 A.M. and 10 A.M. for all 

days of the week: 

      

Function 88  

(Open Window Time) = 8:30 A.M.:  Press 

;

 

8

 

8

 

;

 

0

 

;

 

0

 

8

 

3

 

0

 

:

 

      

Function 89  

(Close Window Time) = 10:00 A.M.:  Press 

;

 

8

 

9

 

;

 

0

 

;

 

1

 

0

 

0

 

0

 

:

 

5.    Exit Program Mode (hold down any key for 3 seconds). 
The lock will now be put in Passage Mode (device physically unlocked) if User 4 (or any Group 1 member) enters their User Code between 
8:30 A.M. and 10 A.M.  If a Group 1 User does not enter their User Code during the specified window, Functions 88/89 remain inactive 

The device will have to be manually locked each night by entering the following command using Function 46: 

;

 

4

 

6

 

:

 

The device can also be programmed to automatically lock (disable Passage Mode) each night at 5 P.M. by using Function 73: 

;

 

7

 

3

 

;

 

0

 

;

 

1

 

7

 

0

 

0

 

:

 

Remember to exit Function Mode when programming is complete. 

 

 
 

Содержание Trilogy ETPDL

Страница 1: ...Access Control Systems with ProxCard Access WI1021C 9 06 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 Publicly traded on NASD...

Страница 2: ...ader and a real time clock calendar that automatically adjusts for Daylight Saving Time and allows for automated programming of events Features three methods of programming 1 all fea tures can be prog...

Страница 3: ...nctions see page 17 21 User Access Methods Keypad Entered User Codes see pages 12 13 16 ProxCard and ProxKey Keyfob see page 13 User Code and ProxCard For highest security see page 13 Batch Enroll Qui...

Страница 4: ...ation Double ended Mini Banana Plug Connector After you create the program in DL Windows and transfer the program from your computer to an AL DTM transfer the program from the AL DTM to the lock s via...

Страница 5: ...r lock to start working To begin programming you must first enter something called Program Mode What is Program Mode Most technical people find working with hardware easy they use tools to make fixes...

Страница 6: ...sses a pre defined level of authority a Programming Level as to their ability to use or make changes to the lock What is a Programming Level The Programming Level defines the range of programming task...

Страница 7: ...associated with User 300 User 297 does this by first entering their own User 297 User Code into the lock keypad When User 300 subsequently enters their User 300 User Code the lock al lows access for...

Страница 8: ...ser Type For example PDL Series locks can hold up to 2000 Users in its programming memory and each User is associated with a User Number see definition of User Number in the previous Terminology secti...

Страница 9: ...Mode Information If a wrong key is pressed during code entry hold any key continuously until the error sound is heard 7 short beeps this will clear the entry Re enter the key sequence again All progr...

Страница 10: ...ode to send or receive data Using DL Windows IBM COMPATABLE LAPTOP OR DESKTOP PC NOTE OBSERVE TAB DIRECTION WHEN INSERTING CABLE INTO LOCK AL PCI CABLE CONNECT TO SERIAL PORT COM 1 4 PDL3000 LOCK Scen...

Страница 11: ...battery pack 2 With battery power disconnected press and hold down for 10 seconds to ensure discharge of all ca pacitors 3 Re install the battery pack lock will sound 3 short beeps If beeps are not he...

Страница 12: ...ode to be 664433 Press 1 664433 664433 Now that the Master Code has been changed there is no need to change it again unless you want to Since you are still in Program Mode you can now proceed directly...

Страница 13: ...three times the card has been enrolled 4 Press to end the process To return to normal operation exit Program Mode see below For example you wish to enroll two ProxCards for User 14 and User 15 respec...

Страница 14: ...Security Access ProxCard User Code Test ProxCard programmed for High Security Access A ProxCard and User Code are both required for access 1 Enter the User Code for the User Number programmed for High...

Страница 15: ...gramming Functions Overview Function 48 Enable Passage Mode See page 22 Function 49 Disable Passage Mode See page 22 Function 50 Return Lock to Normal Passage Mode Schedule See page 22 Function 51 Pas...

Страница 16: ...is Keypad Code Access only Factory Default 123456 See Lock Design Overview on page 5 for more information about Master Codes 3 M USERS Lock Defaults for PDL3000 3500 ETPDL See page 8 Users added will...

Страница 17: ...rogram Mode and pressing 5 1157 008 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions 2 Service Code is a...

Страница 18: ...main 3 13 Clear All Timeout Functions This Function enabled through keypad only CLEAR FUNCTIONS Group Enable Disable Enter the functions below to Enable Disable Groups Functions 14 23 will each overri...

Страница 19: ...ssociation As per the chart on page 8 the lock s default programming from the factory associates certain User Numbers with certain Groups To override these default Group associations Function 35 manua...

Страница 20: ...d ends at 2AM on the programmed date Enter 4 1 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Defa...

Страница 21: ...xample if the clock has already been set to speed up 10 seconds per day and then is found to need an additional 10 seconds then program 20 seconds using Function 43 Example 1 Clock is losing 13 second...

Страница 22: ...ode is entered When the Pass Time expires the lock will re lock automatically Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Pass Time 4...

Страница 23: ...Figure 2 above To abort printing press any key for 3 seconds three short beeps will sound Hold the printer over the lock s infrared sensor as shown in Figure 1 and Figure 2 above For use with DL WINDO...

Страница 24: ...OUT 6 4 64 Disable Remote Input Wire a Normally Open Contact to Wires White White Momentarily close switch to unlock door to allow person to pass through door Enter the functions below to Disable Enab...

Страница 25: ...rammed relay features Subsequent relay feature pro gramming will not take effect while this feature is active Before pro gramming any other relay features press 6 8 0 0 0 to delete this feature Use Fu...

Страница 26: ...8 0 _ _ _ _ _ Day Time 81 Schedule Disable Group 3 8 1 _ _ _ _ _ Day Time 82 Schedule Disable Group 4 8 2 _ _ _ _ _ Day Time 83 Schedule Disable All Groups 8 3 _ _ _ _ _ Day Time 3 Clear All Schedule...

Страница 27: ...Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Note Do not use this feature in Residency mode Scheduled P...

Страница 28: ...of day in 24 hour format for example for 2 15 PM enter 14 15 Scheduled Relay Activation Group 1 Activated 9 1 _ _ _ _ _ Day Time 91 Relay Activation Close Time Window SCHEDULES GROUP 1 ACTIVATED 3 NO...

Страница 29: ...d within this window Group 4 members will be enabled Group 4 members will still need to enter their User Codes to enter For additional information see Group 1 Activated Features on page 30 For day ent...

Страница 30: ...To Disarm a Burglary Control Panel on page 28 If a Group 1 User does not enter their User Code during the specified window Func tions 90 91 remain inactive Function 92 and 93 allow for a window of tim...

Страница 31: ...of the alarm panel Functions 92 93 Use Function 92 and 93 see page 29 to create a window of time where if any Group 1 User Code is entered within the programmed window Group 4 Users will be enabled 1...

Страница 32: ...apply 1 Remote Input switch closed and Function 65 Remote Input enabled 2 Remote Input switch closed and Function 64 Remote Input disabled 3 Failed attempted entry 4 Disabled User or Group 5 Follow A...

Страница 33: ...mber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...

Страница 34: ...programmed Up to only 150 using AL DTM2 For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter...

Страница 35: ...LE A device that permits transfer of program data between a computer and the lock DATE Month Day and Year entered as MMDDYY DAY OF WEEK Sunday through Saturday where 1 Sunday and 7 Saturday DEFAULT De...

Страница 36: ...ll have no obligation under this warranty or otherwise if the product has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire...

Отзывы: