background image

25 

 

;

 

6

 

7

    

;

 

[ _ _ ]

 

:

 

       (Event Number) 

67. Add System Features

 

SYSTEM FEATURES

 

68. Delete All Relay Features added by Function 67.  

 

;

 

6

 

8

   

;

 

0

 

0

 

0

 

:

 

Relay Features

 (12-24. Reserved)

 

 

1.

     

Remote Input switch closed and Function 65 

Remote Input 

enabled.  

Because the Remote Input is enabled by factory default, the Relay will 
energize when the Remote Input switch is closed.  

 

7.    

Scheduled Lock Event.

  Relay energizes for 2 seconds when lock is 

locked by a Schedule. 

2.

     

Remote Input switch closed and Function 64 

Remote Input 

dis-

abled.  

If the Remote Input is disabled with Function 64, the Relay will 

energize when the Remote Input Switch is closed.   

8.    

Scheduled Unlock Event.  

Relay energizes for 2 seconds when lock is 

unlocked by a schedule 

3.

     

Failed attempted entry.

  Relay energizes for 2 seconds when an at-

tempted User Code entry (or ProxCard/Keyfob) fails.

 

9.    

Lock Out.  

Relay energizes for 2 seconds when a Lock Out occurs (i.e. 

number of attempts is exceeded, see Function 60). 

4.     

Disabled User or Group.  

Relay energizes for 2 seconds when a dis-

abled User or disabled Group member enters a User Code (or 
ProxCard/Keyfob). 

10.  

Ambush.  

Relay energizes for 2 seconds when Ambush is tripped.  See 

Function 66, page 26. 

5.     

Follow Access Granted. 

 When a valid User Code is entered into the 

keypad and the lock unlocks, the Relay energizes for 2 seconds.  Com-
pare with Event 31. 

11.  

First Key Press.  

Relay energizes for 2 seconds at the first key press of 

any sequence. 

6.

     

Group 1 User Code.  

Relay energizes for 2 seconds when a scheduled 

Group 1 User Code (or ProxCard/Keyfob) is entered.  See Function 90, 
page 30. 

31.  

Follow Access Granted--No Time Limit.**  

When a valid User Code is 

entered into the keypad and the lock unlocks, the Relay energizes for 
the 

same amount of time as the programmed Pass Time

.  (The Pass 

Time is the length of time the lock stays unlocked after a valid 
User Code is entered.  See functions 52-54).  Use this feature for 
remote monitoring or other activation as this feature works independ-
ently of all other relay options.  Programming this feature will supersede 
all other programmed relay features.  Subsequent relay feature pro-
gramming will not take effect while this feature is active.  Before pro-
gramming any other relay features, press 

;

 

6

 

8

 

;

 

0

 

0

 

0

 

:

 to delete this feature.  

Use Function 67 to program 

one or more 

lock events and the Relay will energize when the programmed event(s) listed below oc-

curs.  For example, program 

;

 

6

 

7

 

;

 

3

 

:

 and when an attempted entry fails (such as a User who enters an 

incorrect or un-programmed User Code), the Relay will energize for 2 seconds.  

Note:

  For more information about the 

Remote In-

put

, see page 11 (Wiring, Remote Input) and page 26 (Function 65).  

 

 

4

 

System Options 

 

25.  Disable Sounder

 

26.  5 sec. Delayed Entry * 
27.  15 sec. Delayed Entry *

 

28.  45 sec. Delayed Entry * 

Remote Input Functions

 

29. 

Toggle Passage Mode.  

Remote Input toggles Passage 

Mode.   

30. 

Forced Unlock Follows Remote Input.

**  When Remote 

Input activated, the Relay will energize regardless of its cur-
rent state. 

32. 

Remote Input Disables Unit.

** 

 

Regardless of the current 

state, that state will remain unchanged (and keypad will be 
disabled) for the duration of Remote Input switch closure. 

*  Features 26, 27 & 28 will delay User Codes 12 and higher only (except 297, 298 and 299). 
** Features 30, 31 & 32 should be used with External DC Power unless feature is used for short a duration and infrequently (sustained 
closure of remote input or Relay will drain batteries, and scheduled events will not occur during sustained closure of remote input).  
Sustained closure of remote input may affect proper audit trail operation. 

NOTE:  

Enter 

;

 

6

 

7

 

;

 

0

 

0

 

0

 

:

 to delete all Relay Features added by Function 67 (identical to Function 68).

 

PC Communication Functions

 

33.  Remote Input Puts Unit in PC Communication Mode 

Enter 

;

 

6

 

8

   

;

 

0

 

0

 

0

 

:

 to delete all Relay Features added by Function 67.   

 

4

 

Programming Functions (cont'd) 

Ambush Function 

1.  

Connect relay to a device able to properly monitor dry contacts for an 

Ambush 

condition. 

2.  

Program the Relay for 

Ambush Tripped

 using Program Function 67(10) above. 

3.  

Set the Ambush Code using Program Function 66.  

4.  

When the Ambush Code is entered followed by a valid User Code, the relay will close for 2 seconds. 

Notes:  

The Ambush Code defaults to 

99

.  An error will sound if you try to program a new User Code starting with the Ambush Code. 

Содержание Trilogy ETPDL

Страница 1: ...Access Control Systems with ProxCard Access WI1021C 9 06 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 Publicly traded on NASD...

Страница 2: ...ader and a real time clock calendar that automatically adjusts for Daylight Saving Time and allows for automated programming of events Features three methods of programming 1 all fea tures can be prog...

Страница 3: ...nctions see page 17 21 User Access Methods Keypad Entered User Codes see pages 12 13 16 ProxCard and ProxKey Keyfob see page 13 User Code and ProxCard For highest security see page 13 Batch Enroll Qui...

Страница 4: ...ation Double ended Mini Banana Plug Connector After you create the program in DL Windows and transfer the program from your computer to an AL DTM transfer the program from the AL DTM to the lock s via...

Страница 5: ...r lock to start working To begin programming you must first enter something called Program Mode What is Program Mode Most technical people find working with hardware easy they use tools to make fixes...

Страница 6: ...sses a pre defined level of authority a Programming Level as to their ability to use or make changes to the lock What is a Programming Level The Programming Level defines the range of programming task...

Страница 7: ...associated with User 300 User 297 does this by first entering their own User 297 User Code into the lock keypad When User 300 subsequently enters their User 300 User Code the lock al lows access for...

Страница 8: ...ser Type For example PDL Series locks can hold up to 2000 Users in its programming memory and each User is associated with a User Number see definition of User Number in the previous Terminology secti...

Страница 9: ...Mode Information If a wrong key is pressed during code entry hold any key continuously until the error sound is heard 7 short beeps this will clear the entry Re enter the key sequence again All progr...

Страница 10: ...ode to send or receive data Using DL Windows IBM COMPATABLE LAPTOP OR DESKTOP PC NOTE OBSERVE TAB DIRECTION WHEN INSERTING CABLE INTO LOCK AL PCI CABLE CONNECT TO SERIAL PORT COM 1 4 PDL3000 LOCK Scen...

Страница 11: ...battery pack 2 With battery power disconnected press and hold down for 10 seconds to ensure discharge of all ca pacitors 3 Re install the battery pack lock will sound 3 short beeps If beeps are not he...

Страница 12: ...ode to be 664433 Press 1 664433 664433 Now that the Master Code has been changed there is no need to change it again unless you want to Since you are still in Program Mode you can now proceed directly...

Страница 13: ...three times the card has been enrolled 4 Press to end the process To return to normal operation exit Program Mode see below For example you wish to enroll two ProxCards for User 14 and User 15 respec...

Страница 14: ...Security Access ProxCard User Code Test ProxCard programmed for High Security Access A ProxCard and User Code are both required for access 1 Enter the User Code for the User Number programmed for High...

Страница 15: ...gramming Functions Overview Function 48 Enable Passage Mode See page 22 Function 49 Disable Passage Mode See page 22 Function 50 Return Lock to Normal Passage Mode Schedule See page 22 Function 51 Pas...

Страница 16: ...is Keypad Code Access only Factory Default 123456 See Lock Design Overview on page 5 for more information about Master Codes 3 M USERS Lock Defaults for PDL3000 3500 ETPDL See page 8 Users added will...

Страница 17: ...rogram Mode and pressing 5 1157 008 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions 2 Service Code is a...

Страница 18: ...main 3 13 Clear All Timeout Functions This Function enabled through keypad only CLEAR FUNCTIONS Group Enable Disable Enter the functions below to Enable Disable Groups Functions 14 23 will each overri...

Страница 19: ...ssociation As per the chart on page 8 the lock s default programming from the factory associates certain User Numbers with certain Groups To override these default Group associations Function 35 manua...

Страница 20: ...d ends at 2AM on the programmed date Enter 4 1 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Defa...

Страница 21: ...xample if the clock has already been set to speed up 10 seconds per day and then is found to need an additional 10 seconds then program 20 seconds using Function 43 Example 1 Clock is losing 13 second...

Страница 22: ...ode is entered When the Pass Time expires the lock will re lock automatically Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Pass Time 4...

Страница 23: ...Figure 2 above To abort printing press any key for 3 seconds three short beeps will sound Hold the printer over the lock s infrared sensor as shown in Figure 1 and Figure 2 above For use with DL WINDO...

Страница 24: ...OUT 6 4 64 Disable Remote Input Wire a Normally Open Contact to Wires White White Momentarily close switch to unlock door to allow person to pass through door Enter the functions below to Disable Enab...

Страница 25: ...rammed relay features Subsequent relay feature pro gramming will not take effect while this feature is active Before pro gramming any other relay features press 6 8 0 0 0 to delete this feature Use Fu...

Страница 26: ...8 0 _ _ _ _ _ Day Time 81 Schedule Disable Group 3 8 1 _ _ _ _ _ Day Time 82 Schedule Disable Group 4 8 2 _ _ _ _ _ Day Time 83 Schedule Disable All Groups 8 3 _ _ _ _ _ Day Time 3 Clear All Schedule...

Страница 27: ...Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Note Do not use this feature in Residency mode Scheduled P...

Страница 28: ...of day in 24 hour format for example for 2 15 PM enter 14 15 Scheduled Relay Activation Group 1 Activated 9 1 _ _ _ _ _ Day Time 91 Relay Activation Close Time Window SCHEDULES GROUP 1 ACTIVATED 3 NO...

Страница 29: ...d within this window Group 4 members will be enabled Group 4 members will still need to enter their User Codes to enter For additional information see Group 1 Activated Features on page 30 For day ent...

Страница 30: ...To Disarm a Burglary Control Panel on page 28 If a Group 1 User does not enter their User Code during the specified window Func tions 90 91 remain inactive Function 92 and 93 allow for a window of tim...

Страница 31: ...of the alarm panel Functions 92 93 Use Function 92 and 93 see page 29 to create a window of time where if any Group 1 User Code is entered within the programmed window Group 4 Users will be enabled 1...

Страница 32: ...apply 1 Remote Input switch closed and Function 65 Remote Input enabled 2 Remote Input switch closed and Function 64 Remote Input disabled 3 Failed attempted entry 4 Disabled User or Group 5 Follow A...

Страница 33: ...mber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...

Страница 34: ...programmed Up to only 150 using AL DTM2 For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter...

Страница 35: ...LE A device that permits transfer of program data between a computer and the lock DATE Month Day and Year entered as MMDDYY DAY OF WEEK Sunday through Saturday where 1 Sunday and 7 Saturday DEFAULT De...

Страница 36: ...ll have no obligation under this warranty or otherwise if the product has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire...

Отзывы: