6
●
The room must be ventilated by means of an air intake positioned at
fl
oor level and protected with a grill.
Make sure the grill does not reduce the passage section.
●
The air in
fl
ow from adjacent rooms is allowed providing that those rooms are in depression with respect to
the atmosphere and that
there are not
fi
replace or fan installed.
When the appliance is installed outdoor,
i.e. on balcony or terrace, make sure it is not directly exposed to atmospheric agents to prevent any damage
to components which would lead to a warranty invalidation. It is recommended to provide the boiler with a
protective casing/box against bad whether conditions.
●
Check the technical data reported on the packing and on the rating plate located on the inside of
the front casing. Also check that the burner is appropriate for the type of gas to burn.
●
Make sure that the pipes and fittings used for the gas service are perfectly tight and that there are
no gas leaks.
●
Prior to start-up, the central heating pipes should be
fl
ushed to remove any residues that could compromise
the operation of the appliance.
●
The appliance can be regarded as being electrically safe when it has been connected to an efficient earth
system installed in accordance with the requirements of current safety standards. This fundamental safety
requirement must be checked and veri
fi
ed. In case of doubt, have the electrical system checked by a quali-
fi
ed electrician. The manufacturer will not be held liable for any damage or injury caused as a result of an
ineffective or non-existent earth system.
●
The domestic power supply must be checked by a qualified electrician to ensure that it can support the
maximum power absorption of the appliance, as indicated on the appliance data plate (positioned on the
inside of the front casing). In particular, make sure that the cable ratings are adequate for the power ab-
sorbed.
●
Do not use adapters; multiple sockets or extension leads to connect the appliance to the mains power
supply.
●
The appliance must be connected to the mains power supply through an appropriate electrical isolator in
accordance with the current wiring regulations.
When using an electrical appliance, a few fundamental rules must be observed:
●
Do not touch the appliance with damp or wet parts of the body or when barefoot
●
Do not pull on the electric wires
●
Do not leave the appliance exposed to atmospheric elements (rain, sun, etc,) unless these conditions have
been expressly provided for.
●
Do not allow the appliance to be used by children or anyone unfamiliar with its operation.
●
The user must not replace the power supply cable.
●
If the cable is damaged in any way, switch off the appliance and have the cable replaced by a suitably
quali
fi
ed electrician.
Содержание SERADENS SRD 20
Страница 1: ...SERADENS SRD 20 27 36 PREMIX CONDENSING BOILER INSTALLATION OPERATING and MAINTENANCE INSTRUCTIONS...
Страница 2: ...Code No A 1 4 3 Publishing Date 241109 Revision Date 241109...
Страница 31: ...31 80 48 5 313 48 5 111 5 187 111 5 80 163 137 122 106 131 SRD 36...
Страница 65: ...65 7 8 Troubleshooting...
Страница 67: ......