PARAMETER P07 – CENTRAL HEATING TIMER
6. Use buttons ‘+’ and ‘-‘ to modify the value of the parameter
within the prescribed limits:
00 = 0 x 5
s. = 0 s.
90 = 90 x 5
s. = 450 s. (7,5 min)
The default value is 36 = 180 s. = 3 min
7. Press and release button ‘S’ to con
fi
rm. The parameter
number (P07) will appear on the display.
8. Switch off the appliance and switch it back on again to
render the new parameter operative.
PARAMETER P08 – CENTRAL HEATING PUMP OVERRUN
TIMER
6. Use buttons ‘+’ and ‘-‘ to modify the value of the parameter
within the prescribed limits:
00 = 0 x 5
s. = 0
s.
90 = 90 x 5
s. = 450 s. (7,5 min)
The default value is 36 = 180
s. = 3 min
7. Press and release button ‘S’ to con
fi
rm. The parameter
number (P08) will appear on the display.
8. Switch off the appliance and switch it back on again to
render the new parameter operative.
PARAMETER P09 – D.H.W PUMP OVERRUN TIMER
6. Use buttons ‘+’ and ‘-‘ to modify the value of the parameter
within the prescribed limits:
00 = 0 x 5
s. = 0
s.
90 = 90 x 5
s. = 450
s. (7,5 min)
The default value is 18 = 90
s. = 1.5 min
7. Press and release button ‘S’ to con
fi
rm. The parameter
number (P09) will appear on the display.
8. Switch off the appliance and switch it back on again to
render the new parameter operative.
P 08
S
S
S
S
18
P 09
P 07
36
S
S
36
Содержание SERADENS SRD 20
Страница 1: ...SERADENS SRD 20 27 36 PREMIX CONDENSING BOILER INSTALLATION OPERATING and MAINTENANCE INSTRUCTIONS...
Страница 2: ...Code No A 1 4 3 Publishing Date 241109 Revision Date 241109...
Страница 31: ...31 80 48 5 313 48 5 111 5 187 111 5 80 163 137 122 106 131 SRD 36...
Страница 65: ...65 7 8 Troubleshooting...
Страница 67: ......