Cleaning the D.H.W heat exchanger
(see
fi
g. 24)
●
Close the shut-off valve and drain the domestic
hot water circuit and central heating circuit of
the boiler;
●
Use a 4 mm Allen key to unscrew the four screws
securing the heat exchanger to the multiplex
unit;
●
Remove the heat exchanger from the left side of
the boiler, note its orientation;
●
De-scale the heat exchanger by chemically
washing the plates
●
Fit new rubber washer, inserting them in their
housings on the multiplex unit;
●
Re-assemble the heat exchanger and compo-
nents following the above procedure in reverse
order;
●
Fill the system with water and check for any
leaks from the joints.
Part replacement:
Ignition and/or
fl
ame detection electrodes
(see
fi
g. 25)
●
Un-Plug the electrode wires;
●
Slacken the
fi
xing screws;
●
Remove the electrodes. When
fi
tting the new
ones, check that the seals are not damaged.
Replace if necessary;
●
Reconnect the wires and re-assemble the com-
ponents following the above procedure in re-
verse order;
●
Switch on the power supply and restart the ap-
pliance;
Fig. 2
ionisation
electrode
ignition
electrode
Fig. 1
d.h.w heat
exchanger
fixing
screws
If the boiler does not restart, check the posi-
tions of the electrodes (especially the ignition
electrode). Make sure that original position
and distances between the electrodes and
the burner are respected to avoid a boiler mal-
function).
24
25
Содержание SERADENS SRD 20
Страница 1: ...SERADENS SRD 20 27 36 PREMIX CONDENSING BOILER INSTALLATION OPERATING and MAINTENANCE INSTRUCTIONS...
Страница 2: ...Code No A 1 4 3 Publishing Date 241109 Revision Date 241109...
Страница 31: ...31 80 48 5 313 48 5 111 5 187 111 5 80 163 137 122 106 131 SRD 36...
Страница 65: ...65 7 8 Troubleshooting...
Страница 67: ......