54
Safety thermostat (see
fi
g. 26)
●
Disconnect the connecting wire;
●
Unscrew the
fi
xing screws and remove the
thermostat;
●
Replace the thermostat and re-assemble
the components following the above proce-
dure in reverse order;
●
Switch on the electricity, water and gas sup-
plies and restart the appliance.
Heating sensor (see
fi
g. 26)
●
Un-Plug the connecting wire;
●
Replace the sensor and re-assemble the
components following the above procedure
in reverse order;
●
Switch on the electricity, water and gas sup-
plies, open the shut-off valves and
fi
ll the
central heating circuit. Then restart the ap-
pliance, remembering to discharge any air
that may be trapped in the system;
Gas valve (see
fi
g. 27)
●
Disconnect the joints and remove the gas
pipe connecting the gas valve to the ven-
turi.
●
Disconnect the gas feed pipe and valve
ring-nut at the bottom of the room-sealed
chamber.
●
Remove the
fl
anged elbow coupling of the
existing valve and
fi
t it to the new valve;
also
fi
t a new cork washer.
●
Replace the gas valve and re-assemble the
components following the above procedure
in reverse order.
●
Replace all the gas seals.
●
Fully tighten the gas connections.
●
Switch on the electricity, water and gas sup-
plies and check for any gas leaks using a
soapy solution or leak detector spray;
heating
sensor
safety
thermostat
gas valve
Fig. 2
Fig. 1
26
27
Содержание SERADENS SRD 20
Страница 1: ...SERADENS SRD 20 27 36 PREMIX CONDENSING BOILER INSTALLATION OPERATING and MAINTENANCE INSTRUCTIONS...
Страница 2: ...Code No A 1 4 3 Publishing Date 241109 Revision Date 241109...
Страница 31: ...31 80 48 5 313 48 5 111 5 187 111 5 80 163 137 122 106 131 SRD 36...
Страница 65: ...65 7 8 Troubleshooting...
Страница 67: ......