477275_f
15
Safety instructions
level falls to the OFF height (02/b). The float
switch must be able to move freely on the surface
of the water.
3.4
Product overview (01)
No.
Component
1
Pump outlet
2
Handle
3
Cable clamp
4
Inlet screen
5
Pump housing
6
Mains cable
7
Combination adapter
8
Notch for rope attachment
9
Connection for separate suction hose
10
Float switch (DIVE 6500/34 only)
3.5
Scope of supply
The pump is supplied ready for operation with
combination nipple, two covers for separate tap-
ping of water and operating instructions.
4
SAFETY INSTRUCTIONS
DANGER! Danger from contact with live
parts!
A defect in the pump or the extension ca-
ble can result in serious injury!
■
Disconnect the connector plug from the
mains immediately.
■
Connect the device via an earth leakage cir-
cuit breaker with a rated leakage current of
< 30 mA.
CAUTION! Danger of injury from hot wa-
ter
After extended use against the closed pres-
sure side (> 10 min.), the water in the pump can
become very hot and may escape uncontrolled!
■
Disconnect the pump from the mains supply
and allow the pump and water to cool down.
■
Check the water level on the suction side.
■
Check the leak-tightness of the lines.
■
Check the installation of the suction and
pressure lines.
■
Put the pump into operation again only after
all the faults have been remedied!
■
Never lift, transport or affix the pump by the
mains cable. Do not pull the mains cable in
order to pull the mains plug out of the socket.
■
Unauthorised modifications or conversions to
the pump are prohibited. Repairs may only
be carried out by our customer service.
■
Disconnect the mains plug before working on
the device. Protect the mains plug against
moisture.
■
Only use the pump and extension cable if
they are in flawless technical condition. Dam-
aged appliances must not be operated.
■
Maintain a safe distance to persons or ani-
mals or switch off the pump if animals ap-
proach.
Electrical safety
■
The pump may not be operated while people
are in the pool or pond.
■
The mains voltage at your location must cor-
respond to the information on the mains volt-
age in the Technical Data. Do not use any
other supply voltage.
■
The appliance must only be operated on
electrical equipment in accordance with DIN/
VDE 0100, parts 737, 738 and 702. A circuit
breaker of 10 A must be installed for fuse
protection.
■
Only use an extension cords which are de-
signed for outdoor use – minimum cross-sec-
tion 3 x 1.5 mm
2
, quality of H07RN-F as per
DIN 57282/57245 with splash-proof plug
socket. Always fully unwind cable drums.
■
Check the condition of you extension cable
prior to every use.
5
INSTALLATION
5.1
Connecting the pressure line (01)
NOTE
The combination nipple can be
trimmed to suit the selected hose connection.
Use the largest possible hose diameter.
1. Screw combination nipple (01/7) with seal
ring into pump outlet port (01/1).
2. Connect hose to combination nipple.
3. Fasten mains cable (01/ 6) to the pressure
line using cable ties.
4. Unwind the mains cable completely.
5. Insert the mains plug into the power socket.
Содержание 113037
Страница 53: ...477275_f 53 2 1 2 2 3 3 1 3 2 35 C 3 3 3 3 1 15 20 3 3 2 DIVE 5600 44 150 7...
Страница 57: ...477275_f 57 AL KO 10...
Страница 58: ...RS 58 DIVE 5600 44 DIVE 6500 34 11 12 AL KO www al ko com service contacts 13 xxxxxx x...
Страница 112: ...RU 112 DIVE 5600 44 DIVE 6500 34 2 1 2 2 3 3 1 3 2 35 C 3 3 3 3 1...
Страница 116: ...RU 116 DIVE 5600 44 DIVE 6500 34 7 3 1 8 8 1 1 01 4 9 AL KO...
Страница 117: ...477275_f 117 10 11 12 AL KO www al ko com service contacts...
Страница 118: ...RU 118 DIVE 5600 44 DIVE 6500 34 13 xxxxxx x...
Страница 120: ...UA 120 DIVE 5600 44 DIVE 6500 34 2 2 3 3 1 3 2 35 C 3 3 3 3 1 15 20 3 3 2 DIVE 5600 44 150 7...
Страница 124: ...UA 124 DIVE 5600 44 DIVE 6500 34 8 1 1 01 4 9 AL KO...
Страница 125: ...477275_f 125 10 11 12 AL KO www al ko com service contacts...
Страница 126: ...UA 126 DIVE 5600 44 DIVE 6500 34 13 xxxxxx x...
Страница 127: ...477275_f 127...