Page 5
MECHANICAL ATTACHMENT OF LOGIC BOX
The Universal II has two options for mounting:
1. Through hole mounting. The through hole mounting holes provided on the Universal II are .177 inches
in diameter and suitable for #8 or M4 screws. These allow inserting screws from the top side and into
threaded holes on the customer’s back panel.
2. Mounting with threaded inserts. There are four threaded inserts in the enclosure bottom which are M6 X 1.0.
These allow screws to be inserted from behind the customer’s back panel and into these inserts on the
Universal II enclosure bottom.
3. The Universal 2 logic box must be mounted close enough to the monitor to allow the monitor wiring harness
sufficient slack to allow the monitor to travel through its full range. The logic box overall dimensions and
mounting hole dimensions are given in Figure 2-1.
4. Monitors and Turrets designed for use with the Universal II come fitted with a harness and connector ready
for direct plug-in to the Universal II. While these are configured for “plug and play” installation, removal of the
connector to run through a bulkhead may be necessary from time to time. In that event, or in the event of
troubleshooting, Table 2-2 is provided for reference.
5-35/64
REF
8-21/32 REF
4-23/32 REF
3-3/16
REF
8.031
3.228
.748 REF
.315 REF
1
06
08
08
1
04
1
M6 x 1.0 BRASS INSERT
MOLDED FLUSH TO
BOTTOM SURFACE (TYP) 4
NOTE:
ENCLOSURE MAY BE MOUNTED FROM THE TOP
WITH A #8 OR M4 SCREW THRU THE ENCLOSURE
OR FROM THE BOTTOM WITH A M6x1.0 SCREW.
Ø.177 HOLE
(TYP) 4
FIGURE: 3
Содержание SEVERE DUTY 3491
Страница 2: ......
Страница 35: ...33 1 2 1 2 NH 2 1 2 NPT 02 14 1 2 13 9 16 14 3 16 90 65 90 20...