Installation (Cont.)
Fitting
guidelines
The cooker is manufactured to work with three-phase alternating current
(400V 3N~50Hz). The voltage rating of the cooker heating elements is 220-
240V. Adapting the cooker to operate with one-phase current is possible
by appropriate bridging in the connection box according to the connection
diagram (Fig. 16). The connection diagram is also found on the cover of
the connection box. Remember that the connection wire should match the
connection type and the power rating of the cooker.
The connection cable must be secured in a strain-relief clamp.
CAUTION!
Remember to connect the safety circuit to the connection box terminal
marked with
ELECTRICAL
CONNECTION
Caution
!
All electrical work should be carried out by a suitably qualified and authorized electrician.
No alterations or willful changes in the electricity supply should be carried out.
Fitting
guidelines
The cooker is manufactured to work with three-phase alternating current (380-415V 3N~50
Hz). The voltage rating of the cooker heating elements is 220-240V. Adapting the cooker
to operate with one phase current is possible by appropriate bridging in the connection box
-
box according to the connection diagram below. The connection diagram is also found on t
he cover of the connection box. Remember that the connection wire should match the
connection type andthe power rating of the cooker.
CONNECTION DIAGRAM
Caution! Voltage of heating elements 220-240V
Caution! In the event of any connection the safety
Wire must be connected to the
E terminal.
Recommended
type of
connection
lead
1
For 220-240V earthed one-phase
connection, bridges connect 1-2-3
terminals and 4-5 terminals, safety
wire to
.
L1
N
E
H05VV-F3G4
2
For 380-415/220-240V earthed two-
phase connection, bridges connect
2-3 terminals and 4-5 terminals, the
safety wire to
L1
L1
E
N
N
L2
L2
H05VV-F4G2,5
3
For 380-415/220-240V earthed three-
-
phase connection, bridges connect 4-5
terminals, phases in succession 1,2
and 3, earth to 4-5, the safety wire to
.
N
N
E
L1
L1
L2
L3
H05VV-F5G1,5
L1=R, L2=s, L3=T, N=earth terminal, E=safety wire terminal
1
2
3
4
The connection cable must be secured in a strain-relief clamp.
.
Before connecting the cooker to the power supply it is important to read the information
connection diagram.
Caution
!
Remember to connect the safety circuit to the connection box terminal marked with
.
The fixing line connected must be equipped with the all-pole disconnection device
provided by breakaway the contact under overvoltage category III according to the
the wiring rules.
on the data plate and the
23
. Before connecting the oven to the power supply make sure
to read the information on the data plate and the connection diagram.
Fig. 16
Earth
Earth
E=Earth terminal, N=Neutral wire terminal
Earth
and 3, Neutral
connect 4-5
contacts