The detector should be installed on a flat stable surface, for example on the wall
of a house or on a fence. If the detector is installed on an unstable surface, this
may lead to false alarms.
The top beam of the detector should be aimed parallel to the ground. If the area is not
flat, the installation height is calculated from the highest point of the monitored area.
When choosing a location, consider 2 main factors: signal strength and
detection zone.
Signal strength
Locate MotionCam Outdoor in a place with stable Jeweller and Wings signal
strength (2-3 bars in the Ajax app). When choosing a place for installation,
consider the distance between the detector and the hub and the presence of any
obstacles between the devices hindering the radio signal passage: walls,
intermediate floors, or large-size objects located in the room.
Be sure to check the Jeweller and Wings signal strength at the installation site. If the
signal strength is low (a single bar), we cannot guarantee stable operation of the security
system! At the very least, relocate the device as repositioning even by 20 cm can
significantly improve the signal reception.
Note that MotionCam Outdoor does not work with ReX radio signal range
extenders, so connect it directly to the hub.
Detection zone
The detection distance is adjusted using the Detection Distance scrollbar on the
rear panel of the detector. When choosing the installation location, consider the
maximum detection range of the detector. It depends on the sensitivity, the
position of the Detection Distance scrollbar, the type and speed of the person’s
movement (running, walking), and the ambient temperature.