Indication when pressing the power button
Indication
Event
Lights up red while the button is pressed
Pressing the power button when the detector is
on
Lights up green while the device is being
activated
Turning on
First lights up red, then flashes three times and
goes off
Turning off
Active detector indication
Indication
Event
Lights up green for 1 second
Alarm, masking, or tamper triggering
Flashes red after the first power on
Hardware error. The detector needs to be
repaired, please contact
Flashes red a few minutes after being installed
in the mount
Calibration failed — something was obstructing
the detector’s view during calibration, or it was
not installed correctly.
Recalibrate the detector. To do this, remove the
device from the mount and reinstall it.
Recalibration will start automatically. Make sure
that nothing obstructs the view of the detector
Lights up green for a few seconds
Connecting the detector to the hub
In case of alarm, masking, or tamper triggering,
slowly lights up and goes out in green
Detector batteries need to be replaced.
Functionality testing
The Ajax security system has several tests for choosing the right installation
place for the devices. MotionCam Outdoor tests do not start straight away but
not later than over a single hub-detector ping period (36 seconds under default
settings of the hub). You can change the ping period of devices in the Jeweller
menu of the hub settings.
There are 4 tests available for MotionCam Outdoor:
Содержание MotionCam
Страница 32: ......