FS2 Frame Synchronizer/Converter v3.0 38 www.aja.com
2. Turn the SELECT knob to access menu 5 Pwr Supply Alarm. The default
alarm setting is Normal.
3. Turn the ADJUST knob one click clockwise to change the setting to
Suppress, which turns off the alarm so that it will never come on.
4. Turn the SELECT knob clockwise again to access menu 6.1 Vid1 Format
Alarm. Changing menus confirms the new Pwr Supply Alarm setting.
5. Now change the Vid1 setting, using the ADJUST knob.
6. Continue by turning SELECT one click to access the 6.2 Vid2 Format Alarm
setting and again one click to access the 7 Reference Alarm setting. Change
the settings using the ADJUST knob, if you wish.
Turn the SELECT knob to
scroll through parameter
menus.
SELECT ADJUST
5 Pwr Supply Alarm
Normal
Press the
CONFIG button
PS Alarm Menu
Current Setting
Labels (none)
Turn the ADJUST
knob to change
settings.
CONFIG
Multiple Parameter Menus: Video 1 ProcAmp
These steps explain how to surf and change multiple parameter menus, such as
the Vid1 ProcAmp settings.
1. Press the VIDEO 1 Menu Group button.
2. Turn the SELECT knob as necessary to display menu 11.0 ProcAmp.
3. Turn the ADJUST knob to change the value setting from OFF (default) to ON.
Turn SELECT knob to scroll
to menu 11.0 ProcAmp On/Off.
Use ADJUST to turn On. Turn
SELECT again to select/adjust
Gain, Black, Hue, and Sat.
SELECT ADJUST
11.0 ProcAmp
On
SDI 1 1080i59.94
Press the
VIDEO 1 button
Parameter Menu
Current Settings
Labels
Change setting
by turning the
ADJUST knob.
VIDEO
1
4. Turn the SELECT knob clockwise to access menu 11.1 ProcAmp Gain and set
the Gain as desired using the ADJUST knob.
5. Turn the SELECT knob one click clockwise to confirm the setting and
advance to the 11.2 ProcAmp Black menu. Turn ADJUST to set the black
level.