Shenzhen Aituo Automation Device Co.,Ltd
24
FAQ summary
Cleaning and attention matters
Cleaning matters
:
1.Clean a correlation fiber every 2 hours
(
with a cotton swab Dipped in alcohol)
2. Clean the up grippers every 4hours
(
with a cotton swab Dipped in alcohol)
3.Clean the pressing module every 8 hours( take down for cleaning)
Other attention matters
:
1, After finished daily work, remember to clean the machine cutting edge and soldering
Phenomenon
Analysis
Solutions
Pseudo Soldering,
fake soldering,
Soldering iron head turn black
Clean it with high
temperature cotton swab
Soldering iron has not pressed the
wires
Add the soldering iron
move down distance
Soldering iron moving down too
much
Reduce soldering iron
moving down distance
Soldering iron, solder wire,
pressed wire are not in the same
vertical plane
Re-adjust
soldering
displacement, short
circuit
1.Grippers dirty
;
2.Bottom grippers are dirty,
caused positioning errors
Clean
Up and bottom grippers are not in
coincidence
Check the grippers
;
adjust the shifting
setting
Position module loose,
displacement
Adjust grippers, tighten
nuts
Vibration, nuts loose
Tighten the nuts
Outer cores too wide
The jacket stripping length is too
long
Adjust the cutting length
1.0-1.2MM
Grippers up and down without
registration accuracy
Check whether it is
loose, adjust
Belt (Chain) reduce
the speed suddenly
Optical head and the bottom
gripper locate surface are dirt,
optical fiber head can not catch
the positioning gripper
Cotton swab dipped in
alcohol to clean these
parts
Optical fiber amplifier numerical
set too high
Adjust the numerical
Feeding pathway
stuck
There is any other things ,or the
pathway no alignment
Clean up and adjust the
pathway