background image

 21 

 

Suburban DynaLine Owner's Manual 04/2021 Rev.4

  Suburban Applied Products by Marvair, Inc.  Limited Product Warranty 

Marvair Inc., warrants its Suburban Applied Products to be free from defects in materials and workmanship under normal use to the 

original purchaser for the period of time in the table below. If any part of your Suburban AP product fails within 24 months from the 

date of the original start-up, Marvair will furnish without charge, EXW Cordele, Georgia, the required replacement part. The owner 

must provide proof of the date of the original start-up. The contractor’s invoice, the certificate of occupancy, or similar documents are 

examples of acceptable proof of the date of the original start-up.

Suburban Applied Products

90 Days

1

 DOA (Dead on Arrival) labor coverage (See Suburban AP Flat Rate Labor Guidelines)

2 Year Parts ONLY Warranty on Entire Unit

2,3

Additional 3 Years Parts Only coverage on the Compressor

3

Additional 8 Years Parts Only Coverage on the Heat Exchanger

2,3

1

If any part of your Suburban AP unit fails within 90 days of the commencement of the warranty, Marvair, Inc.  will furnish without charge, EX Works, Cordele, Georgia, the required 

replacement part and pay for the labor to replace the part in accordance with the Suburban AP Flat Rate Labor Guidelines.

2

All OTR (over the road) applications that are moved from one location to another: Factory Warranty applies only up to the point of initial start-up and test at all OEM 

manufacturing locations or subsequent facility. Once it goes into OTR service, the warranty expires immediately for compressor and sealed system components. This OTR 

exemption does not apply to relocatable classrooms, construction or office trailers.

3

All warranty replacement parts shall be shipped Ground only. Expedited shipping is available upon request for additional cost.

The responsibility of the equipment owner includes:

1.  To operate the equipment in accordance with the manufacturer’s instructions.
2.  To provide easy accessibility for servicing.
3.  To check and reset any circuit breaker(s) and/or disconnect(s) prior to calling for service.
4.  To keep the unit clean and free of dirt and containment and replace filters as required.
5.  To keep the outdoor coil clean and free of leaves, paper, or other debris.
6.  To pay the charges incurred when any of the above have not been done.
7.  To pay for repair or replacement of any material or part other than those within the Marvair, Inc. unit or controller.

Marvair, Inc.,  will not be responsible for labor after 90 days, transportation costs, delays or failures to complete repairs caused by events 

beyond our control (labor hours incurred due to required site-specific training, time waiting to gain access, or extended drive time for 

remote sites). This warranty does not cover:

1.  Any transportation, related service labor, diagnosis calls, filter, driers, refrigerant, or any other material charges.
2.  Damages caused by shipping, accident, abuse, negligence, misuse, fire, flood, or Acts of God.
3.  Damages caused by operating or staging the unit in a corrosive environment.
4.  Damages caused by improper application of the product.
5.  Damages caused by failing to perform proper routine maintenance.
6.  Expenses incurred for erecting, disconnecting or dismantling the product or installing the replacement part(s).
7.  Products not installed or operated according to the included instructions, local codes, and good trade practices.
8.  Products moved from the original installation site.
9.  Products lost or stolen
10.  Consequential damages or incidental expenses including losses to persons, property or business.
11.  Modifications to original unit after it leaves the factory, such as breaking into any part of the sealed systems unless authorized   

in advance in writing by Marvair, Inc.. 

12.  Damages as a result of operating as a construction site cooler / dehumidifier.

When service is required, it must be performed during normal working hours (8:00 AM - 5:00 PM) Monday - Friday and must be performed 

by Marvair Inc.,  personnel or a designated Service Representative. 
The owner of the product may ship the allegedly defective or malfunctioning product or part to Marvair Inc.,, at such owner’s expense, 

and Marvair Inc., will diagnose the defect and, if the defect is covered under this warranty, Marvair Inc. will honor its warranty and 

furnish the required replacement part. All costs for shipment and risk of loss during shipment of the product to Marvair Inc. and back to 

the owner shall be the responsibility and liability of the owner. Upon written request by an owner, Marvair Inc. may arrange for remote 

diagnosis of the allegedly defective or malfunctioning product or part but all costs for transportation, lodging and related expenses 

with regard to such diagnostic services shall be the responsibility and liability of the owner.
An owner requesting performance under this Warranty shall provide reasonable access to the allegedly defective or malfunctioning 

product or part to Marvair Inc. and its authorized agents and employees.
THIS WARRANTY CONSTITUTES THE EXCLUSIVE REMEDY OF ANY PURCHASER OF A MARVAIR HEAT PUMP OR AIR CONDITIONER AND 

IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF 

MERCHANTABILITY OR FITNESS FOR USE, TO THE FULLEST EXTENT PERMITTED BY LAW. IN NO EVENT SHALL ANY IMPLIED WARRANTY 

OF MERCHANTABILITY OR FITNESS FOR USE EXCEED THE TERMS OF THE APPLICABLE WARRANTY STATED ABOVE AND MARVAIR 

SHALL HAVE NO OTHER OBLIGATION OR LIABILITY. IN NO EVENT SHALL MARVAIR BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL 

DAMAGES OR MONETARY DAMAGES.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE-TO-STATE. 

Some states do not allow limitations or exclusions, so the above limitations and exclusions may not apply to you.  

03/16/2020 New

Содержание DYNA07AC

Страница 1: ...ot store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical...

Страница 2: ...Your unit should be inspected immediately after unpacking to determine if any damage is present due to shipping or handling If any damage is discovered do not install the unit Notify the transportatio...

Страница 3: ...ot install in an alcove or recess Special sleeve and grille applications must be brought to the attention of Suburban Applied Products as they may impair the operation of the unit IMPORTANT Installati...

Страница 4: ...heavy under conditions of extreme humidity for extended periods of time The drain tube assemblies may be installed externally on rear flange of the wall sleeve or underneath the wall sleeve to the ext...

Страница 5: ...STALLATION FRONT GAS HOOKUP WALL INSTALLATION FRONT GAS HOOK UP Figure 5 GASKET NOTCH FOR OPTIONAL REAR GAS HOOKUP BE SURE DRAIN HOLES ARE TO OUTSIDE REAR FRONT SLEEVE TOP INSERT SIDES BETWEEN TOP FLA...

Страница 6: ...xisting DynaLine units with new DynaLine 3 units it is recommended to replace the wall sleeve as well During the replacement process the sleeve may become damaged or incorrectly aligned If sleeve inst...

Страница 7: ...al supply Refer to Figure 10 for centerline location of gas connection and electrical connection when unit is installed into wall sleeve NOTE This unit is factory set for 230 volt operation If you wis...

Страница 8: ...l Gas 5 W C 7 W C Liquefied Petroleum LP Gas 11 W C 13 W C Water Column OPERATING PRESSURE All units for burning natural gas are equipped with a valve having a built in regulator preset at 3 5 W C pre...

Страница 9: ...an speed 1 Open the manual shut off valve The valve is fully open when the handle is level or parallel to the gas line Never attempt to operate unit with manual valve partially closed 2 Depress System...

Страница 10: ...m on the evaporator coil during extended cooling operation To eliminate frost formation a de ice switch in the compressor circuit will sense a frost condition and open the compressor circuit Upon temp...

Страница 11: ...ve will close Do not ignore the alarm and shutdown Immediately move to a spot where fresh air is available preferably outdoors Find a phone in an area where the air is safe and call your building mana...

Страница 12: ...In rare instances the sounding of a warning device can cause temporary or permanent hearing loss Telephone lines needed to transmit alarm signals from a premises to a central station may be out of ser...

Страница 13: ...ect electrical supply before cleaning unit or performing any maintenance The unit should be inspected by a qualified service person yearly before turning the unit on heat for the winter Particular att...

Страница 14: ...BURNER OBSERVATION WINDOW YELLOW OUTER FLAME ERRATIC PATTERN ORANGE YELLOW INNER FLAME ERRATIC PATTERN Figure 17 Filter Removal 1 The filter is located behind the cabinet front Remove cabinet front by...

Страница 15: ...OTES The efficiency rating of this unit is a product thermal efficiency rating determined under continuous operating conditions and was determined independent of any installed system IMPORTANT Childre...

Страница 16: ...BK BL Y BK Y R R R R O BR BK BK COMPRESSOR RELAY Y Y L2 R BK L1 WHITE YELLOW BROWN BLACK RED BLUE ORANGE COLOR R W Y BR BL BK CODE O FLAME CONDENSER BK BL MODULE BOARD O BR 1 2 3 4 BUILT IN T STAT PRO...

Страница 17: ...EET 3m HORIZONTALLY C CLEARANCE TO WINDOW OR DOOR THAT MAY BE OPENED a a L CLEARANCE ABOVE PAVED SIDEWALK OR PAVED DRIVEWAY LOCATIED ON PUBLIC PROPERTY 7 FEET 2 13m a D VERTICAL CLEARANCE TO VENTILATE...

Страница 18: ...ILLE A ARCHITECTURAL STYLE GRILLES NATURAL FINISH ALUMINUM GRILLE STOCK NO 1420 DARK BRONZE FINISH GRILLE STOCK NO 1418 INTRODUCTION These architectural grilles are designed to be used as an optional...

Страница 19: ...adaptor is 43 1 4 On model DYNA12AC and DYNA16AC additional lengths may be added If additional length is required connector assembly No K 10734 may be used No more than two 2 connectors may be used Ma...

Страница 20: ...ified licensed professionals for the installation of hard wired carbon monoxide detectors a In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an...

Страница 21: ...vice labor diagnosis calls filter driers refrigerant or any other material charges 2 Damages caused by shipping accident abuse negligence misuse fire flood or Acts of God 3 Damages caused by operating...

Страница 22: ...e in heat when the temperature drops below about 45 F when the unit is in STANDBY HEAT and COOL mode This mode can be disabled if desired If freeze protection is desired when operated from a wall moun...

Страница 23: ...IRE OR TYPE 150 C WIRE WHERE SPECIFIED OR ITS EQUIVALENT 105 C THERMOPLATIC 14 A W G WIRE TGS 200 C 18GA STRANDED TEFLON COATED ROCKER SWITCH R BL O N C FLUE LIMIT R HIGH LOW L1 COMB COND BLWR FLAME D...

Страница 24: ...WHITE BLACK 2 4 3 1 BL BL W W BK IGNITOR RELAY BK ROCKER SWITCH BK BL R R O O 24VAC GND CONT GAS VALVE POWER SUPPLY BOARD CO DETECTOR BL Y BK GY R BL T T NC C T C A NO BR BL BL Y Y BR O 4 3 2 1 BL O...

Страница 25: ...k for fault numbers associated with the HEAT mode Press the SYSTEM key again to go from HEAT to COOL Check for fault numbers associated with the COOL mode The SERVICE menu will Time Out automatically...

Страница 26: ...the lockout expires 15 Loss of pressure switch lockout Pressure switch contact open during heating operation After 5 trips of the pressure switch a 20 minute lockout begins code 15 is registered and t...

Страница 27: ...it de cet appareil ou de tout autre appareil QUEFAIRESIVOUSSENTEZUNEODEURDEGAZ Ne pas tenter d allumer d appareils Ne touchez aucun interrupteur Ne pas vous servir des t l phones se trouvant dans le b...

Страница 28: ...imm diatement apr s le d ballage pour d terminer la pr sence d ventuels dommages imputables au transport et aux manutentions S il y a des dommages ne pas installer l appareil Aviser imm diatement le...

Страница 29: ...install e conform ment aux indications de la figure 5 ou 6 lorsque l appareil est plac dans la gaine murale l air de ventilation est pr lev dans l atmosph re ext rieure Ne pas installer l appareil da...

Страница 30: ...ement en s curit de l appareil ou l installation correcte des canalisations d arriv e de gaz et du c ble d alimentation lectrique 8 Le panneau avant de la caisse est exp di avec le ch ssis Pour garant...

Страница 31: ...ALE SURFACE DE FINITION DU MUR EXT RIEUR 1 INSTALLATION MURALE RACCORDEMENT PAR L AVANT LA CANALISATION DE GAZ Figure 5 SOMMET JOINT ENCOCHE POUR CONNECTION OPTIONELLE EN ARRI RE DU GAZ VEILLER PLACER...

Страница 32: ...qu elle d passe d au moins 1 4 po au del de la surface finale du mur ext rieur voir figure 5 NOTE Pour une installation avec gaine murale et d passement dans la pi ce de 4 po ou plus on doit utiliser...

Страница 33: ...ommutateur de configuration no 1 du thermostat la position on Voir figure 11 Pour r initialiser les contr les teignez puis rallumez le REMARQUE Raccordement thermostat distance remplace le thermostat...

Страница 34: ...iatement en amont du point de raccordement de l appareil la canalisation de gaz Lors de tout test de pressurisation ex cut sur le syst me une pression sup rieure 1 2 lb po2 rel 3 5 kPa il faut que l a...

Страница 35: ...er 2 Appuyez simultan ment sur les boutons WARMER COOLER et FAN nF va s afficher quand la protection contre le gel est d sactiv e et FP va s afficher quand la protection contre le gel est activ e REMA...

Страница 36: ...mostat manifeste encore une demande de refroidissement NOTE Une p riode d attente de 5 minutes est incorpor e entre les p riodes de fonctionnement du compresseur Apr s chaque interruption du fonctionn...

Страница 37: ...r et appelez votre gestionnaire d immeuble et leur demander d avoir l unit de Dynaline et ou d autres appareils combustion dans l habitation v rifier le bon fonctionnement Ne pas revenir une chambre o...

Страница 38: ...es M me les personnes veill es peuvent ne pas remarquer l alarme si celui ci est couvert par le bruit d une cha ne hi fi radio climatiseur ou d un autre appareil ou par la circulation automobile Dispo...

Страница 39: ...e s jour La manette de commande est situ dans l angle inf rieur gauche avant de l appareil Pour acc der la manette de commande on doit faire pivoter l avant de la caisse vers l avant voir figure 15 NO...

Страница 40: ...Cette inspection doit inclure un contr le complet du fonctionnement de l appareil ceci incluant tous les composants lectriques et m caniques REMARQUE Si le panneau de fa ade de la caisse a t d pos ava...

Страница 41: ...usieurs instructions relatives la s curit qu il convient d observer au cours de la saison de chauffage pour garantir le fonctionnement en s curit de l appareil 1 Ne jamais faire fonctionner l appareil...

Страница 42: ...ration L appareil devrait tre soumis une inspection avant l utilisation et au moins chaque ann e par un technicien qualifi Il peut tre n cessaire de nettoyer plus fr quemment s il y a une accumulation...

Страница 43: ...BK BL Y BK Y R R R R O BR BK BK COMPRESSOR RELAY Y Y L2 R BK L1 WHITE YELLOW BROWN BLACK RED BLUE ORANGE COLOR R W Y BR BL BK CODE O FLAME CONDENSER BK BL MODULE BOARD O BR 1 2 3 4 BUILT IN T STAT PR...

Страница 44: ...EET 3m HORIZONTALLY C CLEARANCE TO WINDOW OR DOOR THAT MAY BE OPENED a a L CLEARANCE ABOVE PAVED SIDEWALK OR PAVED DRIVEWAY LOCATIED ON PUBLIC PROPERTY 7 FEET 2 13m a D VERTICAL CLEARANCE TO VENTILATE...

Страница 45: ...CTUREL STYLE NATUREL GRILLE EN ALUMINIUM FINITION STOCK 1420 DARK GRILLE DE FINITION BRONZE STOCK 1418 INTRODUCTION Ces grilles d coratives sont con ues pour l utilisation comme option ou grille de re...

Страница 46: ...DYNA12AC et DL3 s rie DYNA16AC on peut ajouter une section additionnelle N est pas recommand d utiliser sur les mod les avec thermostats int gr s Si une section additionnelle est n cessaire on peut u...

Страница 47: ...Les dommages caus s par l utilisation ou la mise en sc ne de l unit dans un environnement corrosif 4 Les dommages caus s par une mauvaise application du produit 5 Les dommages caus s par le d faut d e...

Страница 48: ...essous d environ 45 F 13 C quand l appareil est dans l un des modes ATTENTE CHAUFFAGE ou REFROIDISSEMENT Ce fonctionnement peut tre d sactiv si on le d sire Si une protection contre le gel est d sir e...

Страница 49: ...E APPLIANCE MUST BE REPLACED IT MUST BE REPLACED WITH TYPE 105 C WIRE OR TYPE 150 C WIRE WHERE SPECIFIED OR ITS EQUIVALENT 105 C THERMOPLATIC 14 A W G WIRE TGS 200 C 18GA STRANDED TEFLON COATED ROCKER...

Страница 50: ...WHITE BLACK 2 4 3 1 BL BL W W BK IGNITOR RELAY BK ROCKER SWITCH BK BL R R O O 24VAC GND CONT GAS VALVE POWER SUPPLY BOARD CO DETECTOR BL Y BK GY R BL T T NC C T C A NO BR BL BL Y Y BR O 4 3 2 1 BL O...

Страница 51: ...uche SYSTEM pour passer de HEAT COOL V rifiez les num ros de d faut associ s au mode COOL Le menu SERVICE expirera automatiquement et reviendra au r glage pr c dent REMARQUE 1 Pour supprimer les d fau...

Страница 52: ...n du verrouillage 15 Perte de verrouillage du pressostat Contact pressostat ouvert pendant le chauffage Apr s 5 d clenchements du pressostat un verrouillage de 20 minutes commence le code 15 est enreg...

Отзывы: