Heat Exchanger Locations and
Clearances
• Position the heat exchangers so that even heat is distributed
throughout the RV interior.
•
The first heat exchanger on the loop will output the most
interior heat.
• It is best practice to place the heat exchanger in an area
where it can be easily accessed for maintenance.
•
Place the heat exchangers as close to the floor as possible
for best performance.
• If a heat exchanger is kept in the fresh water storage bay,
then the last heat exchanger in the coolant loop should be
used.
• The heating air supply may be fresh or recirculated air that
is drawn from a clean area not likely to be contaminated.
Aqua-Hot advises against placing a heat exchanger on the
slide-out section of any vehicle due to the high probability
of damage occurring to the heating loop from moving parts.
Figure 67
Figure 68
Mounting the Heat Exchangers
1. Cut out a 2.5” x 10” (7cm x 26cm) opening for each heat
exchanger outlet and cold-air return grate as shown in
Figure 64.
2. Mount each heat exchanger permanently into place. There
are 4 tabs on both sides - see Figure 77.
3. Install the hot-air outlet and cold-air return grate.
A minimum of supply ventilation cross-sectional area of at
least 29in
2
(74cm
2
) must be supplied to each heat exchanger.
If the toe-kick area is inadequate to house a heat exchanger
for regular installation, a plenum assembly may be purchased
to redirect air via ducting. Refer to Figure 71.
1
2
3
4
5
1. Hot Air Outlet Vent
2. Air Ducting Hose
3. Plenum
4. Cozy Heat Exchanger
5. Toe Kick Board
Mounting the Heat Exchangers
Figure 70
Figure 69
Figure 71