Component Cut-Aways
System Features
©Aqua-Hot®
125DN Installation Manual
REV 220419
©Aqua-Hot®
125DN Installation Manual
REV 220419
p. 9
p. 8
Aqua-Hot 125DN
All vehicle installations must comply with the requirements
listed in the Recreational Vehicle Industry Association’s
(RVIA) ANSI/NFPA 1192 Handbook for Recreational Vehicle
Standards.
System Specifications
Diesel Burner
Heat Flow ....................................................8,500 to 17,000 BTU
Diesel Fuel Consumption...............................0.08 to 0.13 gal/hr
Operating Pressure (med heat)....................................36.25 PSI
Flow Rate (minimum).....................................................66 gal/hr
DC Power
Consumption .....................................................................12-21W
Operating Voltage Range ............................................. 9.6 to 15V
Operating Temperatures
Burner Operation ..................................................... -40 to 176°F
Burner Storage................................ .........................-40 to 248°F
Fuel Pump Operation ................................................. -40 to 86°F
Fuel Pump Storage ...................................................-40 to 194°F
Physical Specifications
Dimensions................................................8.6”L x 3.6”W x 5.8”H
Weight ..................................................................................4.8 lbs
Figure 2
NOTE:
This product label (shown above) is attached to
the side of the burner and provides a ready reference to
specifications, test standards, and important safety notices.
1. Fluid Circulation Pump
2. Tempering Valve
3. Aqua-Hot Controller
4. Antifreeze and Water Heating Solution Tank
5. AC Electric Element
6. AC Activation Relay
7. Plate-to-plate Heat Exchanger
8. Three-Way Valve
9.
Zone Air-Bleed Valve
10.
Fluid Expansion Port (to overflow bottle)
11.
Zone Return
12. Fluid Fill Port
13.
Zone Supply
14. Service Panel
15. External Diesel Burner Supply
16. External Diesel Burner Return
17. Domestic Cold-Water Inlet
18. Domestic Hot-Water Outlet
19. Domestic Low Point Drain
20. Cabinet Drain
1
2
3
4
5
6
7
8
9
Figure 3
NOTE:
The side panel in the view above has been made
transparent to aid in the explanation of the heater. DO NOT
remove the side panel. Doing so risks irreparable damage
to the Aqua-Hot. Only remove the service panel for service.
11
12
13
14
16
17
18
10
9
19
20
Figure 5
3
Figure 6
Figure 4
15
Содержание AHE-125-DN1