background image

 

2

  TC4-T1O.rev.05

TC4-T10:   24-HOUR TIMER CONTROL

Œ 

INTRODUCTION

The TC4-T10 is a timer designed to control farm equipment.  It uses an internal clock

to operate up to 24 different operation cycles.  At each cycle start, the timer activates

a dry contact.  Manual start/stop and skip-a-day functions are included.  A four-digit

display and a push-button make programming easy.  Additional features include:

-  a battery back-up for keeping time in case of a power failure

-  overload protection on the output

-  a 115/230 VAC - 50/60Hz power supply

-  an alarm output

-  the unit can be connected to a computer communications module

• 

CONNECTIONS

To connect the controller, refer to the wiring diagram enclosed with this user's manual.

ð

Set the voltage switch to the appropriate voltage.

ð

Use the electrical knockouts provided at the bottom of the enclosure.  Do not make

additional holes in the enclosure, particularly on the side of the enclosure when using

a computer communications module.

Ž 

MOUNTING INSTRUCTIONS

Remove the four screws on the front cover and lift the cover.  Mount the enclosure on

the wall using three screws.  Be sure the electrical knockouts are at the bottom of the

enclosure in order to prevent water from entering the controller. Insert the screws in the

mounting holes provided in three corners of the enclosure and tighten.  Fasten the three

black caps provided with the controller onto the three mounting holes.

Although fuses at the input and outputs of the controller protect its circuits

in case of an overload or overvoltage, we recommend installing an additional

protection device on the controller's supply circuit.

The room temperature where the controller is located MUST ALWAYS

REMAIN BETWEEN 32°F AND 104°F (0°C TO 40°C).

To avoid exposing the controller to harmful gases or excessive humidity, it is

preferable to install it in a corridor.

DO NOT SPRAY WATER ON THE CONTROLLER

• 

PRECAUTIONS

 

2

  TC4-T1O.rév.05

TC4-T10:   MINUTERIE 24 HEURES

Œ 

INTRODUCTION

Le TC4-T10 est une minuterie destinée à commander des systèmes agricoles.  Une

horloge interne commande une sortie avec 24 cycles d’opération.  Un contact sec est

activé à chaque début de cycle.  La minuterie comprend des commandes manuelles de

départ et d’arrêt ainsi qu’un mode pour fonctionner un jour sur deux.  Un affichage à

quatre chiffres et un bouton-poussoir facilitent la programmation.  De plus, la

minuterie comprend les caractéristiques suivantes :

-  une pile d’alimentation de secours pour garder l’heure en cas de panne

-  une protection contre les surcharges et les surtensions

-  une alimentation 115/230 VAC - 50/60Hz

-  une sortie d’alarme

-  la possibilité de communiquer avec un ordinateur

• 

PRÉCAUTIONS

La circuiterie de la minuterie est protégée contre les surcharges et les surtensions par

des fusibles sur son entrée et ses sorties.  Nous recommandons cependant l’installa-

tion d’un dispositif de protection additionnelle sur le circuit d’alimentation.

La température de l’endroit où la minuterie est installée

DOIT EN TOUT TEMPS DEMEURER ENTRE 0

o

 ET 40

o

C (entre 32

o

 et 104

o

F).

Pour éviter une exposition à des gaz nocifs ou à une humidité excessive, il est préfé-

rable d’installer la minuterie dans un corridor.

NE PAS ARROSER LA MINUTERIE

• 

BRANCHEMENT

Pour brancher l’appareil, se référer au diagramme de branchement joint à ce manuel.

ð

Placer le sélecteur de tension à la position appropriée.

ð

Utiliser les entrées de câbles pré-percées sous le boîtier.  Ne pas faire de trous additionnels

dans le boîtier, en particulier sur le côté du boîtier lorsqu’un module de communication par

ordinateur est utilisé.

Ž 

MISE EN PLACE

Enlever les quatre vis du couvercle et soulever le couvercle. Fixer le boîtier au mur à l'aide de trois

vis. S'assurer que les entrées de câbles sont placées sous le boîtier afin de réduire le risque

d'infiltration de l'eau. Insérer les vis dans les trois trous de fixation prévus et bien serrer. Placer

les trois bouchons d'étanchéité fournis avec le contrôleur sur les trous de fixation.

Содержание TC4-T10

Страница 1: ...R 2 TEMPS DE DÉPART HR MIN ARRÊT MANUEL SORTIE PM TC4 T10 MINUTERIE 24 HEURES TC4 T10 24 HOUR TIMER CONTROL 24 HOUR TIMER CONTROL CLOCK SELECT SET TC4 T10 SKIP A DAY START TIMES HR MIN RUNNING TIME MIN SEC MANUAL STOP ONE CYCLE STOP OUTPUT PM M 890 00161 rev 05 REV 00 ...

Страница 2: ... PRECAUTIONS 2 TC4 T1O rév 05 TC4 T10 MINUTERIE 24 HEURES Œ INTRODUCTION Le TC4 T10 est une minuterie destinée à commander des systèmes agricoles Une horloge interne commande une sortie avec 24 cycles d opération Un contact sec est activé à chaque début de cycle La minuterie comprend des commandes manuelles de départ et d arrêt ainsi qu un mode pour fonctionner un jour sur deux Un affichage à quat...

Страница 3: ...NT DOIT ÊTRE EFFECTUÉ PAR UN ÉLECTRICIEN RECONNU ET ÊTRE CONFORME AUX NORMES LOIS ET RÈGLEMENTS EN VIGUEUR COUPER LE COURANT À LA SOURCE AVANT D EFFECTUER LE BRANCHEMENT AFIN DE PRÉVENIR LES CHOCS ÉLECTRIQUES ET DES DOMMAGES AUX ÉQUIPEMENTS TC4 T10 rev 05 3 ALL WIRING MUST BE DONE BY AN AUTHORIZED ELECTRICIAN AND MUST COMPLY WITH APPLICABLE CODES LAWS AND REGULATIONS BE SURE POWER IS OFF BEFORE DO...

Страница 4: ...mande utilisé pour sélectionner la commande 2 Affichage numérique affiche l heure et les autres paramètres 3 Lampe témoin pour la sortie s allume lorsque le relais de la sortie est activé 4 Lampe témoin pour l heure P M s allume lorsque l horloge est en mode 12 heures et l heure est dans l après midi 5 Lampe témoin pour le mode 1 jour sur 2 s allume lorsque le mode 1 jour sur 2 est activé 6 Lampe ...

Страница 5: ...our la durée du temps de marche Un seul temps de marche est défini pour tous les cycles Chaque cycle peut être activé ou désactivé séparément De plus le mode 1 jour sur 2 permet d activer les cycles à tous les deux jours TC4 T10 rev 05 5 USING THE CONTROLLER THE DISPLAY A flashing value on the display means that the value can be modified using the adjust ment knob Otherwise the parameter cannot be...

Страница 6: ...seconds n Press the push button to store the new running time 6 TC4 T1O rév 05 Exemple de programmation des cycles NOTA i Si deux cycles ont des heures de départ identiques un seul des deux est activé ii Si un cycle est censé commencer alors qu un autre cycle est déjà activé le deuxième cycle commencera dès que le premier cycle est terminé et ce pour la durée complète du temps de marche Cycle 1 Cy...

Страница 7: ... sur le bouton poussoir Les minutes clignotent n Régler les minutes à l aide du bouton d ajustement n Appuyer sur le bouton poussoir pour stocker la nouvelle valeur en mémoire et sélectionner un autre cycle TC4 T10 rev 05 7 DEFINING THE START TIMES n Set the selection knob to the START TIME position The display shows CH 1 and the number 1 representing the cycle number is flashing n Using the adjus...

Страница 8: ...tart skipping on the following day USING THE SKIP A DAY FUNCTION 8 TC4 T1O rév 05 L arrêt manuel est effectué Heure de départ prévue pour le cycle no 1 L arrêt manuel est désélectionné Heure de départ réelle du cycle no 1 Temps Temps de marche MODE UN JOUR SUR DEUX Ce mode de fonctionnement active les cycles un jour sur deux Vous pouvez com mencer par sauter le jour en cours ou le lendemain à minu...

Страница 9: ...he à l humidité et à la poussière La température de la pièce où l appareil est installé DOIT EN TOUT TEMPS DEMEURER ENTRE 0 ET 40o C entre 32 et 104o F TC4 T10 rev 05 9 ALARM CONDITIONS An alarm is set off when one of the following situations occurs i the battery is low ii the permanent memory chip is not working properly iii a power failure occurs iv the microprocessor is defective BACK UP BATTER...

Страница 10: ...b r a n c h e m e n t e s t i n c o r r e c t L e f u s i b l e F 6 s u r l a l i m e n t a t i o n e s t b r û l é L a p o s i t i o n d u s é l e c t e u r d e t e n s i o n n e c o r r e s p o n d p a s à l a t e n s i o n d e l i g n e u t i l i s é e L e r u b a n p l a t e n t r e l e c i r c u i t d u c o u v e r c l e e t l a b a s e e s t d é b r a n c h é R é e n g a g e r l e d i s j o ...