background image

Relay

Connection

 

8A, 240 V AC

24V DC

18

16

15

Supply

Connection  

OPTIONAL

LOAD > 1 mA 

24 -240 V
AC/DC

TECHNICAL SPECIFICATIONS 

SUPPLY CHARACTERISTICS

Power Consumption (Max.)

8A (Res.) @ 240 VAC / 24 VDC

Mechanical Life Expectancy
Electrical Life Expectancy

     1 x 10 

Switching Frequency (Max.)

1800 Operations / h @ rated load

Status Indication on  panel

Red LED - Relay ON

+/- 0.5 % of selected  range

Variation in timing due to voltage change

+/- 0.2% 

20 ms Max. (DC High), 40 ms Max. (AC High), 100 ms Max. (Low) 
300 k 

Variation in timing due to temperature change

93% (Rh)
Base / Din - Rail (35 mm Sym.) 

24 - 240 VAC / DC 

5

Ag Alloy

  -20°C to + 65°C

2 x 10 

-10°C to + 55°C

FEATURE CHARACTERISTICS

Cat. No.:

Nominal Supply (  )

Supply 

Frequency

Contact Arrangement
Contact Rating
Contact Material

Functions  Available
Timing Ranges

Signal Sensing Time
Signal Impedance           
Repeat Accuracy

 Operating Temperature 

Humidity (Non-Condensing)
Mounting

1 C/O

+/- 1% 

0.5 VA (@ 24/48 VAC), 4VA (@ 110 to 265 VAC/DC)

7

Refer “Timing diagrams of Functions”

85 g (approx.)

Weight (Unpacked)

Utilization Category 

Dimension (W X H X D) in mm 

17.5 X 89 X 76 

Rated Voltage (Ue):120/240 V:,
Rated Current (le):3.0/1.5 A
Rated Voltage (Ue):125/250 V:,
Rated Current (le):0.22/0.1 A 

Initiate Time
Reset Time

40 ms
< 200 ms

Storage Temperature 

Supply 

Variation

50 to 60 Hz, +/- 2Hz

RELAY OUTPUT CHARACTERISTICS

EMI/EMC

IEC 61000-3-2       Ed. 3.0 (2005-11) Class A  
IEC 61000-4-2       Ed. 1.2 (2001-04) Level  II  
IEC 61000-4-3       Ed. 3.0 (2006-02) Level  III  
IEC 61000-4-4       Ed. 2.0 (2004-07) Level  IV  
IEC 61000-4-5       Ed. 2.0 (2005-11) Level  IV  
IEC 61000-4-6       Ed. 2.2 (2006-05) Level  III  
IEC 61000-4-11     Ed. 2.0 (2004-03) 
IEC 61000-4-29     Ed. 1.0 (2000-08) 

(2005-11) Class B 

CISPR 14-1

 Ed. 5.0 

CISPR 14-1

 Ed. 5.0 (2005-11) Class B 

IEC 60947-5-1       Ed. 3.0 (2003-11) Level IV 

IEC 60068-2-1       Ed. 6.0 (2007-03) 
IEC 60068-2-2       Ed. 5.0 (2007-07) 
IEC 60068-2-6       Ed. 7.0 (2007-12) 5 g 
IEC 60068-2-27     Ed. 4.0 (2008-02) 40 g, 6 ms 
IEC 60068-2-27     Ed. 4.0 (2008-02) 30 g, 15 ms 

IEC 61010-1          Ed. 2.0 (2001-02) 

UL 508

 Ed. 17   (1999-01) <3.5mA 

II 
Reinforced 

IP 20 for Terminal;  IP 40 for Housing 

Safety

Harmonic Current Emissions

Test Voltage Between I/P & O/P

Radiated Susceptibility
Electrical Fast Transient 

 ESD

Surge

Conducted Emission
Radiated Emission

Voltage Dips & Interruptions (AC)
Voltage Dips & Interruptions (DC)

 Conducted Susceptibility

Impulse Voltage Between I/P & O/P
Single Fault

Leakage Current 

Pollution Degree 
Type of Insulation 

Degree of Protection 

Cold Heat
Dry Heat
Vibration
Repetitive Shock
Non-repetitive Shock

Insulation Resistance

Environmental

UL 508

Ed. 17  (1999-01) >2000 M 

IEC 60947-5-1       Ed. 3.0 (2003-11) 2 kV

-15 % to + 10 % of 

7957

h:m

m:s

1h

min

1s

9:59

9:59

999
99.9

999

99.9

999

99.9

AC-15

DC-13

1. Compact size
2. Available with 18 functions
3. Wide timing range from 0.1 sec - 999 h
4. 
5. 3-Digit LCD Display
6. Time & Mode setting through easy key operations.
7. Up/Down Counting Modes
8. Clear LED indication for Relay Status
9. Key Lock Function

Wide operating voltage : 24 to 240 VAC / DC

CAUTIONS:

FEATURES:

FRONT FACIAL:

1. 

PRESET TIME:

 The Timer Duration selected by the

user.
2. 

RUN TIME:

 In Down counting (  ) mode it indicates

the remaining while in Up counting (  ) mode indicates 
the elapsed time. 
3. 

Default Mode:

 Down 

counting (  )

4.Up/Down (    ) blinks during the Timer Duration (T)

LED INDICATION

FOR

RELAY STATUS

SET  ADJ

UP / DN

MODE OR

TERMINAL DETAILS: 

 22 to 14

AWG

3.5 mm

0.4 N.m (3.5 Lb.in)
Terminal screw - M2.5

2

1 x 0.3 to 2.5 mm
Solid Wire 

Wire Strip Length = 6.5 mm. Use Cu wire of 75°C only.

The  timers  shall  be  placed  in  an  enclosure  that  is 
minimum 200% of the size of the timer in the  end use 
application.

 
               
            
            4.8

 
               
            
            3.2

 
               
            
            1.6

AWG

CURRENT (A)

14
16   
18   
20   
22   

8
6.4

Use relay coil Voltage of the same Voltage using for 
Proximity sensor. [Relay coil current should not exceed 
the maximum current Specified by Proximity sensor.]

R

P

L

A1

B1

A2

N

R

R = Relay coil

CONNECTIONS DIAGRAM :

VLL012-00

1.Always  follow  instructions  stated  in  this  product.
2.Before  installation,  check  to  ensure  that  the
specifications  agree  with  the  intended    application.
3.Installation  to  be  done  by  skilled  electrician.
4.Automation  &  Control  devices  must  be  properly
installed so that they are protected against  any risk

5.Using  of  AC  2  wire  Type  Proximity  Sensor:
Please add input relay to prevent false signal sensing 
due to current leakage of proximity sensor as below. 

of involuntary actuations.

OVERALL DIMENSIONS:

35 - mm-

SYMMETRICAL

ALL DIMENSIONS ARE IN mm

17.5

76.0

100.0  C/C

67.0

45.0

89.0

DIN RAIL

BASE MOUNTING

7957

Digital Timer - 18 Functions

RoHS

Отзывы: