ADJ

SET

Programming Instructions

ADJ

ADJ

Confirms counting mode. Program 
Over. 
Timer starts working normally.

Change with ADJ Key (e. g. from 
DOWN to UP)

Change with ADJ Key (e. g. from 9 
to 6)

Change with ADJ Key (e. G. from 3 
to 0)

Confirms 2nd digit selection, now 
3rd digit  of preset Time blinks.

Press  Set  to  confirm  1st  digit 
selection, now 2nd digit blinks

Press  ADJ  key  to  adjust  desired 
preset time digit (e. g. from 5 to 8)

Now UP/DOWN Indicator blinks

Apply power & hold the set key for >3 s. 
                           OR
Press both ADJ & SET key for >3 s after power ON. 
Now follow  the steps given below; 

 

Press ADJ  Key to select range 
(e. g. HM range ‘HM’)

Confirms range selection. 1st digit 
of preset time blinks. (For modes 
‘1’, ’2’ & ‘G’ two preset times ‘On’ &
‘Off’ to be set)

Confirms  function  then  range 
indicator blinks

Press ADJ   Key to   select desired 
function  (e. g. F) 

KEY

DISPLAY

RESULT

F

5:39

HM 

F

5:39

HM 

F

5:39

HM 

F

5:39

HM 

F

8:39

HM 

F

8:39

HM 

F

8:09

HM 

F

8:09

HM 

F

8:06

HM 

F

8:06

HM 

F

8:06

HM 

 00.0

F

8:06

HM 

Timing Diagrams of Functions:

1.ON DELAY [ ]

0

2.CYCLIC OFF/ON {OFF Start,
(Sym, Asym)} [

1

]

13.LEADING EDGE IMPULSE1 [

C

]

4.IMPULSE ON ENERGIZING [

3

]

5.ACCUMULATIVE DELAY ON SIGNAL [

4

]

6.ACCUMULATIVE DELAY ON INVERTED 
SIGNAL [

5

]

7.ACCUMULATIVE IMPULSE ON SIGNAL [

6

]

8.SIGNAL ON DELAY [

7

]

9.INVERTED SIGNAL ON DELAY [

8

]

10.SIGNAL OFF DELAY [

9

]

11.IMPULSE ON/OFF [

A

]

12.SIGNAL OFF/ON- TYPE 1 [

B

]

3.CYCLIC ON/OFF {ON start, (Sym, Asym)} [

2

]

 6. ACCUMULATIVE DELAY ON INVERTED 
 SIGNAL [

5

]

3.CYCLIC ON/OFF {On Start, (Sym, Asym)} [

2

2.CYCLIC OFF/ON {OFF Start, (Sym, Asym)} [

1

4.IMPULSE ON ENERGIZING [

3

]

5.ACCUMULATIVE DELAY ON SIGNAL [

4

]

Functional Description 

1.ON DELAY

  [

0

]

Timing  commences  when  supply  is  present.  R 
energizes  at  the  end  of  the  timing  period.

T-ON and T-OFF can be same or different. The relay 
(R) keeps on  changing its status until power is 
removed. 

This  function  is  quite  similar  to  the  function  ‘1’  but 
initially the relay (R) is ON for period T-ON after the 
power is applied. 

After power ON, R energizes and timing starts. R de-
energizes after timing is over.

Time commences as supply is present and switch B1 is 
open.  Closing  switch  B1  pauses  timing.  Timing 
resumes when switch B1 is opened again. R energizes 
at the end of timing.

Time commences as supply is present and switch B1 is 
closed.  Opening    switch  B1  pauses  timing.  Timing 
resumes when switch B1 is closed  again. R energizes 
at end of timing.

16.TRAILING EDGE IMPULSE 2 [

F

]

17.DELAYED IMPULSE [

G

]

18.

 

INVERTED SIGNAL ON DELAY-TYPE 2 [

H

]

H

When supply is ON, R energizes. When switch B1 is 
closed timing is suspended and remains suspended till 
switch B1 is opened again. Interrupting supply resets 
timer.

7. ACCUMULATIVE IMPULSE ON SIGNAL

 [

6

]

 9.INVERTED SIGNAL ON DELAY [

8

]

VLL012-00

Timing  will  commence  when  supply  is  present  and 
switch B1 is open. R energizes after timing. If B1 is 
closed  during  timing  period,  timing  resets  to  the 
beginning of cycle. 

11.IMPULSE ON/OFF

  [

a

]

Permanent  supply  is  required.  R  energizes  for  the 
timing  period  when  B1  is  opened  or  closed.  When 
timing  commences,  changing  state  of  B1  does  not 
affect R but resets timer.

 

When switch B1 is closed or opened for preset time ’T,’ 
the  relay  changes  its  state  after  time  duration  T.

 

12.SIGNAL OFF/ON

 [

B

]

A  permanent  supply  is  needed.  When  B1  is  closed, 
output relay energizes until timing irrespective of any 
further action of B1.  

13.LEADING EDGE IMPULSE1 

[

c

]

Permanent  supply  is  required.  when  switch  B1  is 
closed, and remains closed output relay energizes until 
timing is over. If B1 is opened during timing, R resets.

14.LEADING EDGE IMPULSE 2

  [

D

]

15.TRAILING EDGE IMPULSE 1

 [

e

]

Permanent  supply  required.  when  B1  is  opened,  R 
energizes and de-energizes when timing is over. If B1 
is closed during timing R resets

.

16.TRAILING EDGE IMPULSE 2

 [

f

]

Permanent  supply  is  required.  When  switch  B1  is 
opened, R energizes and will de-energize when timing 
is over. If B1 is pulsed during timing period it Will have 
no effect on R.

17.DELAYED IMPULSE  [

G

]

when switch B1 is closed, T

OFF

 starts. Relay energizes 

at the end of T

OFF

 period. Then, T

ON  

starts 

irrespective of signal level and relay de-energize at 
the end of T

ON

 period.   

10.SIGNAL OFF DELAY 

 

[

9

]

Permanent  supply  is  required.  R  energizes  when 
switch  B1  is  closed.  Timing  commences  after  S  is 
opened  and  then  the  relay  de-energizes.

Permanent supply required. Timing starts when switch 
B1 is closed. R energizes at end of timing period and 
de-energizes when B1 is opened.

8.SIGNAL ON DELAY

  [

7

]

Timing starts only upon signal ‘B1’ transition high to 
low.  During  timing  or  after  completion  of  Time  (i.e. 
relay on), any signal transition is ignored. To reset the 
timer supply has to be interrupted. 

18.

 

INVERTED SIGNAL ON DELAY-TYPE 2 [

H

]

SET

SET

ADJ

ADJ

KEY FUNCTIONS:

1. Used as ENTER key to jump to next setting
 & save the settings edited.
2. RUN MODE RESTART: Press SET key 
continuous for >3 sec during RUN Mode to 
restart the timing operation.
3. Press SET key once to edit PRESET time in 
RUN mode

1. Used to edit the modes & timing ranges.
2. Keypad LOCK/UN-LOCK: Press ADJ key
 for >3 sec during RUN time mode.

1. Used to enter in program edit mode 
after power ON.