AirSpeed 1030 B48 Installation Guide
DUG01623
Airspan Commercial and Internal Use
39
Warning:
This unit incorporates
double pole
/
neutral fusing
. Both the Line & Neutral have fuses
in them.
Warning:
The onsite source circuit breaker (6A) should be gang operated,
two
(
2
)
pole
(single
phase type).
The following displays the proper steps for DC cable preparation:
1.
Strip back and remove the outer sheath to a length of 9.0mm± 2 (0.35 in) to expose the inner
insulated wires to a length of 13.5mm± 2 (0.53 in). Then strip back 7mm± 2 (0.27 in) of the
inner core insulation.
Figure 40: Stripping Dimensions (DC Cable)
2.
Open the housing lock by sliding up then lift the clamp handle.
Figure 41: Open Housing Lock
3.
Separate the housing into its component sections.
Figure 42: Seperate into Sections
4.
Insert the Gland nut through the other end of the cable.