![Airspan AirSpeed 1030 B48 Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/airspan/airspeed-1030-b48/airspeed-1030-b48_installation-manual_2879151040.webp)
AirSpeed 1030 B48 Installation Guide
DUG01623
Airspan Commercial and Internal Use
38
Figure 37: Insert Gland
11. Tighten the gland nut with a 21mm wrench, to a torque of no more than 2-2.5 Nm (1.47
–
1.84 ft-lb) max.
Figure 38: Tighten Gland Nut
12. Insert the connector into the Copper Ethernet port on the bottom of the chassis. Verify that
the connector’s latch faces the rear of the unit to enable potential unlocking.
13. Close the lever and secure the lock by sliding the secondary lock/button
, so that lever can’t
be lifted.
Figure 39: Secure Housing Lock
5.4 DC Cable Preparation
The following demonstrates the recommended assembly instructions, hardware and tool requirements
for the proper DC cable assembly used by Airspan products.
Note:
Power Cable:
Diameter - 8.4mm to 9.4mm
Wire Size - AWG16 to AWG14
Caution:
Safety - Disconnection of power supply
When AirSpeed unit is connected directly to wiring a suitably rated and easily accessible
circuit breaker shall be incorporated externally to the equipment.
Power source disconnection is required before disconnecting the power connector.