32
2.
Open the housing lock by sliding up then lift the clamp handle,
Figure 14: Open Housing Lock
3.
Separate the housing into its component sections.
4.
Insert the gland nut through the front end of LC Duplex assembly.
Figure 15: Gland Nut on Cable
5.
Insert the “split tightening cone” from the side of the cable.
Figure 16: Insert Tightening Cone on Cable
6.
Insert the “split rubber gland” from side of the cable.
Note:
Make sure to select the correct gland size. Inner diameter of rubber gland is in the range of
4.8 to 6.8mm (0.19
”-0.26”) range.
Figure 17: Insert Rubber Gland on Cable
7.
Pass the LC Duplex cable thru the housing.