5. Periodic Inspection/Maintenance
5
-
9
A030211-1
A070039-1
A000020
5.5.12 Change Filter inside the fuel air-bleeding electromagnetic pump
[Every 1,000 hours]
Turn the cap “1” counterclockwise to remove it, change
the filter “2” inside. (See 5.3.)
As the fuel inside spills out when it is removed, prepare
a fuel receiver.
5.5.13 Clean the strainer provided inside the engine feed pump
[Every 1,000 hours]
Periodically remove the strainer
“1” inside the feed
pump, and clean it.
Remove the strainer
“1” by loosening the joint bolt and
clean it with diesel fuel oil, and also using high air
pressure blow. At this time be sure to replace gasket
.
(See 5.3)
Then after finishing all cleaning jobs, install it again in
reverse steps.
5.5.14 Clean the strainer provided inside the sedimenter entrance
[Every 1,000 hours]
Periodically remove the strainer ”1” inside the sedi-
menter entrance, and clean it.
Remove the strainer ”1” by loosening the joint bolt and
clean it with diesel fuel oil, and also using high air
pressure blow. At this time be sure to replace gasket.
(See 5.3)
Then after finishing all cleaning jobs, install it again in
reverse steps.
1
Joint bolt
1
1
2
Joint bolt
Содержание SDG60S-7A6
Страница 1: ......
Страница 12: ...2 Part Names 2 1 2 1 Internal Components A070010 1 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11...
Страница 56: ...8 Specifications 8 2 8 2 Outline drawing A060509E 1...
Страница 57: ...9 Wiring Diagram 9 1 9 1 Generator Wiring Diagram A050635E...
Страница 58: ...9 Wiring Diagram 9 2 9 2 Engine Wiring Diagram A070003E...
Страница 59: ...10 Piping Diagram 10 1 10 1 Fuel piping A070103E 1...
Страница 61: ......