4. Troubleshooting
4-19
PC14057E
⑥
For the list of diagnostic trouble codes, refer to 4.6.2.
For the detailed countermeasures, refer to “Service manual” published by engine manufacturer.
※
How to clear Logged DTC after repairing troubles is to be performed by pressing “Clear Logged
DTC” or “ALL clear” key.
2. DPF Active Regeneration
In DPF regeneration there are automatic regeneration (self-regeneration / assisted regeneration /
reset regeneration) and manual regeneration (stationary regeneration). Manual regeneration
(stationary regeneration) will be performed by “regeneration switch”, but these forced regenerations
can be done optionally. By using SA-D.
※
For the details of regeneration, refer to 3.1.4.
<
Procedure
>
①
Select
“
Active control
”
from Diagnosis Tests and display
“
DPF Active Regeneration
”
screen.
Requirements for active
regeneration
・
Coolant temperature should be
higher than 60
℃
.
・
No failure influencing
regeneration should exist.
・
At unload speed
When above requirements are
fulfilled, push
“
Set key
”
after
inputting regeneration mode in
command value column.
[Regeneration mode command value]
・
Assisted regeneration
・・・・・
Inputting [1]
・
Reset regeneration
・・・・・・・
Inputting [2]
・
Manual regeneration
・・・・・
Inputting [3]
(
Stationary regeneration)
PC14056E
Input using
▲▼
button
Input
Discount-Equipment.com
Содержание PDS185S-6E1
Страница 1: ...www discount equipment com D i s c o u n t E q u i p m e n t c o m...
Страница 9: ...1 Specification 1 3 1 3 Outline Drawing Unit in A131026 D i s c o u n t E q u i p m e n t c o m...
Страница 10: ...1 Specification 1 4 Unit mm A131025 D i s c o u n t E q u i p m e n t c o m...
Страница 18: ...1 Specification 1 12 1 7 Piping Diagram PC14063E D i s c o u n t E q u i p m e n t c o m...
Страница 19: ...1 Specification 1 13 1 8 Fuel Piping PC14001 D i s c o u n t E q u i p m e n t c o m...