3. Electric System
3-14
Pin No. Line
color
Connection Function
CN2-3 G/R Engine oil pressure switch
When engine oil pressure drops to the set
pressure of emergency stop, it makes emergency
controller Ry4 relay ON and it sends abnormality
signal to ECU to stop engine.
●
Emergency stop set oil pressure :
7.1psi(0.049MPa)[0.49bar]
CN2-4 G/R Compressor air filter
It detects clogging of compressor air filter, and it
enables alarm lamp to blink.
●
Differential pressure for warning function :
More than
0.9psi(6.23kPa)[0.06bar]
CN2-5 G/L Engine air filter
It detects clogging of engine air filter, and it
enables alarm lamp to blink.
●
Differential pressure for warning function :
More
than
0.9psi(6.23kPa)[0.06bar]
CN2-6 B/G Service pressure sensor
Intake negative pressure sensor
Grounding
CN2-7 G Service pressure sensor Vout
terminal
Detection of service pressure.
CN2-8 Y/R Engine controller (ECU) CN5-94
terminal
It outputs engine speed.
●
Revolution ratio (pulse type) :
6 pulses per 1 revolution
CN2-9 G/W Discharge temperature sensor
When discharge air temperature rises over the
emergency stop pre-determined temperature, it
makes emergency controller Ry4 relay ON and it
sends abnormality signal to ECU to stop engine.
●
Emergency stop set temperature : 248°F(120
℃
)
CN2-10
-
NIL
CN2-11 Y
・
Engine controller (ECU) CN5-66
terminal
・
Alternator L terminal
It detects deficiency of charging battery, and it
enables alarm lamp ON.
CN2-12 L/Y Engine controller (ECU) CN5-50
terminal (Preheating lamp)
When preheating, it receives preheat signal from
ECU CN5-50 terminal and it enables preheat
lamp ON.
CN2-13
-
NIL
CN2-14
-
NIL
CN2-15 R/Y Intake negative pressure sensor
Vcc terminal
Power supply (DC5V)
CN2-16 R Service pressure sensor Vcc
terminal
Power supply (DC5V)
CN2-17 Y Intake negative pressure sensor
Vout terminal
Detection of intake negative pressure.
CN2-18 G/Y Fuel sending unit
For detecting residual fuel.
CN2-19 Y/B Engine water temperature sensor
When coolant temperature rises over the
emergency stop pre-determined temperature, it
makes emergency controller Ry4 relay ON and it
sends abnormality signal to ECU to stop engine.
●
Emergency stop set temperature : 230°F(110
℃
)
CN2-20 G/B
・
Engine water temperature sensor
・
Discharge temperature sensor
・
Common of fuel sending unit
Grounding
Discount-Equipment.com
Содержание PDS185S-6E1
Страница 1: ...www discount equipment com D i s c o u n t E q u i p m e n t c o m...
Страница 9: ...1 Specification 1 3 1 3 Outline Drawing Unit in A131026 D i s c o u n t E q u i p m e n t c o m...
Страница 10: ...1 Specification 1 4 Unit mm A131025 D i s c o u n t E q u i p m e n t c o m...
Страница 18: ...1 Specification 1 12 1 7 Piping Diagram PC14063E D i s c o u n t E q u i p m e n t c o m...
Страница 19: ...1 Specification 1 13 1 8 Fuel Piping PC14001 D i s c o u n t E q u i p m e n t c o m...