Preheating control
[ON glow control (Pre-heat)]
When the starter switch is placed “RUN” position automatically the glow plug relay is electrified in
accordance with the time applied to coolant temperature. Being electrified, the preheat lamp goes on
at the same time.
PC14016E
[Simultaneous electrification control]
While starter is working with the starter switch placed on “START” position, glow plug relay is
electrified.
Also the conditions to end simultaneous electrification control is to be ended by engine starting
signal (When the starter switch is operated on the other position than “START” position, glow plug
relay is not electrified).