14
DV50 DV80
(Integral CO
2
Sensor)
EXPERT SETTINGS
DEPLOYMENT WIZARD
AWAY PROFILE
When you want to set the
Away
profile settings, proceed as
follows:
1. The deployment wizard
Away
profile screen is opened.
NOTE
Once you have set the fan speed for the
At home
profile, the fan
speed for the
Away
profile will default to -30% of the
At home
profile fan speed. We recommend this basic amount of ventilation
for the
Away
profile setting. If necessary, you can change it.
2. Set the
Away
profile fan speed as a percentage of the
maximum by using the
Plus
and
Minus
buttons.
3. The
Away
profile fan speed value is now set.
4. Press the
Right arrow
button.
5. The temperature setup screen is opened.
6. Set the desired supply air temperature for the
Away
profile
by using the
Plus
and
Minus
buttons. You can adjust the
temperature in the range of +10°C – +5°C.
7. The
Away
profile supply air temperature is now set.
8. Press the
Right arrow
button.
9. The setup screen for automatic fan speed control, based on the
relative humidity, appears.
10. Use the
Plus
and
Minus
buttons to select whether the
automatic fan speed control, based on the relative humidity, is
used or not.
11. The automatic fan speed control, based on the relative
humidity, is now set.
12. Press the
Right arrow
button.
13. The setup screen for the automatic fan speed control, based on
the carbon dioxide or VOC content, appears.
14. Use the
Plus
and
Minus
buttons to select whether the
automatic fan speed control, based on the carbon dioxide or
VOC content, is used or not.
15. The automatic fan speed control, based on the carbon dioxide
or VOC content, is now set.
16. Press the
OK
button.