4.
SYSTEM COMPONENT ASSEMBLY
Rys. 1
1.
Prepare the reserve parachute container
closing loop, and place it in the container
bottom stiffener. Follow the AAD owner’s
manual to meet the requirements for the
given AAD.
Use materials approved by the given AAD
manufacturer only.
The Feniks harness/container system is
delivered with a closing loop required for the
CYPRES AAD.
The figure shows the way of preparing the
closing loop for the CYPRES AAD. In case of
other AADs, the procedure of preparing the
closing loop may differ from that described in
this Instruction Manual. In such case, prepare
the closing loop following the owner’s manual
for the AAD used.
The recommended length of the closing loop from
disc exit to loop end measures
11
-
16
cm.
ATTENTION!
It may be necessary to adjust the closing loop length upon closing the container. If the parachute was packed, check – prior
to opening the container – whether the loop length was correct. The pilot chute should be compressed in a way preventing
the top of the pilot chute from swinging inside the container.
The force required to pull the deployment handle shall be no less than 2.25 kg and no more than 9.9 kg in directions
ensuring easiest and most difficult deployment (± 45º from the most favourable direction), respectively.
Fot. 10
2.
Place the closing loop (1) in the bottom of the
container, threading it through the grommet
from the inside.
The part of the loop with the disc should be
placed in the pouch (2) to prevent it sliding
out.
1
2