8
Changing Parameter Sets
To change the parameter set that is active, press the
CHANGE PSET
button (Fig. 4) until the desired
parameter set number is displayed.
With each separate press of the button the parameter set numeral will advance upwards through the
highest parameter set that is programmed and then cycle back to parameter set #1. A maximum of 8
parameter sets can be programmed into the iEC controller.
The display for each type of strategy will vary. The main control parameter (Torque, Angle or both) will be
displayed when the Parameter Set is selected. The different strategies will display as follows:
Note:
SCC Firm-
ware Version 3.00 extends
the number of
parameter sets that can be
programmed to 32. The extended parameter sets can be programmed via Toolware 3.0 or greater. For parameter sets 10
-
32, the
numeric Pset LED will flash the first digit, then the second followed by a pause. If any of the parameter sets are
“
Linked
”,
the
CHANGE PSET button will automatically skip to the first Pset of the Linked Pset group. (For information on Linked parameter sets,
see the Setting Parameters section in the ToolWare portion of the user manual.)
Programming the Display Options
The Programmable Display Options feature in the iEC allows the user to select the information that will be
displayed in the Secondary Display Field.
Step 1
Press the
DISPLAY OPTIONS
button (Fig. 4) to access the Display Options Menu.
Immediately a message will appear in the Primary Display Field (Fig. 4) that will indicate which display
option is currently selected.
If no rundowns have been conducted since the most recent Power
-
On of the controller, the Secondary
Display Field will display the default information relating to the current display option.
If rundowns have been conducted since the controller was last Powered
-
On, then the Secondary Display
Field will display the value for that option pertaining to the most recent rundown in the current parameter
set.
!
Example:
PSET #2, Torque Control
Strategy, 25 ft
-
lb Target
Example:
PSET #3, Angle Control
Strategy, 270 Degree Target
ALTERNATING
Example:
PSET #4, Torque Control / Angle Control Strategy,
25 ft
-
lb Target, 270 Degree Target
Main Display Functions