41
APPENDIX E:
Dual Trigger Lever Functionality for Gen 3
-
4 tools
•
Tool will not run unless both switches are pressed within 1 second of each other.
•
If the 1 second timer times out, both switches must be released to reset the timer.
•
If either trigger is released the tool stops.
•
To restart the tool, both switches must be released and pressed within 1 second of
each other again.
•
Note: Logic I/O Run Forward and Run Reverse commands bypass the second trig-
ger functionality.
•
Note: Exceptions to second trigger function exist for Tube Nut Homing sequence.
•
Note: The latching throttle feature is prevented in tools with dual triggers.
APPENDIX D:
Light Assignment for Light Tower and Key Bypass
Light Color
Judgment
Green
Accept
Red
High Torque
Red Flashing
Low Torque
Yellow
High Angle
Yellow Flashing
Low Angle
Blue
Bypass
White
Tool Enabled
White Flashing
Assignable
Lights Strobe
Assignable
Содержание iEC
Страница 1: ...AcraDyne iEC DC Tool Controllers User Guide...
Страница 35: ...35 Appendix B KDM Menu Structures Main Menu Structure Parameter Set up Menu...
Страница 36: ...36 APPENDIX B KDM Menu Structures Administration Menu...
Страница 45: ...45 Notes...
Страница 46: ...46 Notes...
Страница 47: ...47 Notes...