17
Main Menu: 3) Administration Functions
Parameter Set Defaults
Parameter set defaults are the values used to calculate control parameters when using either Quick Start
or Auto Set. This is also the area where units of measurement for all parameters is set.
To access the Parameter Set Default function:
From the MAIN MENU, press
3
for
ADMIN
Press
1
for
SETUP PSET
The following text will be displayed on the KDM display screen:
Navigation and value
-
entry is the same as described in the section
Setting Up Parameter Sets
on pages
12
—
16.
All programmable default values are described below:
TQTARGET%:
The default
torque target
shown when entering quick programming. The value entered is a
percentage of the maximum torque of the tool. For example, if the value entered is 80 and the maximum
torque of the tool is 30 Nm, the default target torque when entering quick programming will be 27.0 Nm.
TQ+/
-
%:
The default percentage used for
high and low torque limit
. The value entered is a percentage
of target torque.
TQTHOLD%:
The default
torque threshold
. The value entered is a percentage of target torque.
TQDSHIFT%:
The default setting for
torque downshift
point. The value entered is a percentage
of target torque.
CYCCOMP%:
The default setting for
cycle complete
torque. The value entered is a percentage
of target torque.
RPMFREE%:
The default setting for
RPM free speed
. The value entered is a percentage of maximum output
speed in revolutions per minute (RPM). 3000 series AcraDyne tools operating at 120V will run at 1/2 of the
programmed speed.
RPMDOWN%:
The default setting for spindle speed after crossing the downshift torque level. The value
entered is a percentage of maximum output spindle speed in revolutions per minute (RPM).
UNITS:
The default engineering units for operation. The KDM is only capable of using one engineering unit for
all parameter sets. Changing the units in this section will affect all parameters sets.
Using the Optional Keypad Display Module (KDM)